My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.orWehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Verizon Facility 430 W Center Street, Manteca Inspection Aug 6, 2013 <br />Name: Address: Date: <br /># <br />C1 <br />C2 M Code Section <br />__ _C ass 1. Iola i C - Cl M - __--_r- - <br />C1 =Class 1 violation• C2 =Class 2 vitiation• M =Minor vitiation <br />Qtr9te`tcords "(asintinued)", <br />204 X CCR 2715(c) Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and sumps <br />if necessary) not inspected; 5 required test dates not checked or noted; 6 employee training not verified <br />205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />208 CCR 2715(f) Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />3 log not kept <br />207 HSC 25281.5(b)(2) Unburied fuel plOng at marinas not visually Ins ected at least daily or log not ke t <br />` Q.bservptlgns . ' - <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 X HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(M1) <br />303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (11111) <br />304 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double wailed UST (M1) <br />305 CCR 2838(f)(1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (M1) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 2631 a) Primary containment is not product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system Is not tight <br />308 X CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to havesecondary containment for piping (includes conventional suction piping) (11112) <br />310 HSC 25291(e) Water in 2^ containment not removed, analyzed & properly disposed of <br />311 CCR 2636(1)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (11111) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br />313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (11112) <br />the spill container empty <br />314 CCR 2635 b 2) Overfill prevention system was overridden or failed to meet overfill requirements (11112) <br />315 HSC 25299(t)(2) Tampering with or disabling teak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) Illegally abandoned UST system <br />A$1792 (20Q Q14) H$ , X6200 2 (intailed b9tWeen 4?!0 !04 and 06!30!94) <br />VPH' eteiX,s )i$C2$260:1 fnshalll�tl'onoraiker'07Id11Qd <br />401 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1 2004, were not submitted <br />402 <br />HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br />HSC 26290-2(c)(1) <br />403 <br />HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br />HSC 25290.2(c)(2) <br />404 <br />HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br />HSC 25290.2(c)(3) <br />405 <br />HSC 26290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />HSC 25290.2(d) liquid or vapor from the primary containment into the secondary containment <br />406 <br />HSC 25290.1(a) interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />HSC 252902 ressure testa roved §1 SWRCB 3 test method deemed a uivalent to 1 or 2 by the SWRCB <br />777777 -77 <br />Emerg�rl :GehbtaWd. stAnisai ." <br />501 CCR 2636(1)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (M1) <br />502 HSC 25281.5(b)(3) Unburied fuel piping not vIsuaIIX Inspected at least monthly or log not kept (M1) <br />U$Ts lg a VAitlt7777777777777 <br />601 HSG 25283.5(a)(1) All extedor surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located In does not provide for secondary containment <br />43133 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.6(a)(5) UST installed atter July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />!Mott-Presssrrized piping '.77 <br />701 1 1 1 1 CCR 2643(d) Daily monitoring of suction piping (pro -January 1, 1984) not performed (M1) <br />Inspedw.. <br />Elena Manzo (209) 953-7699 <br />Received By: <br />U <br />Title: <br />EHD 23-02 Rev 04122!13 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.