Laserfiche WebLink
F__1 <br />r <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd == <br />_ E <br />Facility Name: Facility Address: Date: <br />QUICK SHOP 2072 W YOSEMITE AVE, MANTECA September 19, 2017 <br />MmMij <br />NUNN <br />ME- <br />Item # Remarks <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on March 31, 2017 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by April 30, 2017. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a repeat violation, Class Il. <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. A cold start was performed in <br />May 2017 and testing report was not found on site. These records shall be maintained on site for at least three <br />years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment <br />calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed <br />a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or <br />other test results; (6) results of inventory readings and reconciliations. Immediately locate and maintain all <br />maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br />This is a Class II violation. <br />203 <br />CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site. <br />Records of repairs, linings, and upgrades for the UST system were not found on site. Site had a spill container <br />replaced based on service request SR0077716 and records were not found on site. These records shall be kept on <br />site for the life of the tank. Immediately locate and maintain these records on site and submit copies to the EHD. <br />This is a Class II violation. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. Monitoring plans for tank ID numbers <br />TA0507923, TA0507924, TA0507926, TA0507927 and TA0507928 were not found on site.. A copy of these plans <br />shall be accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class ll. <br />FA0004625 PR0231426 SCO01 09/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />