My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2023 4:26:49 PM
Creation date
6/23/2020 6:48:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />r.o <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />j <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.o[gjabLd <br />Facility Name: Facility Address: Date: <br />QUICK SHkkOP 2072 W YOSEMITE AVE, MANTECA September 19, 2017 <br />LA M.- 0' <br />2-A5 AA <br />10 01 , mo m <br />0 <br />Item # <br />Remarks <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The diesel direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five <br />gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue <br />deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and <br />certified contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately, <br />there is a possibility that the diesel UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />This is an amended report from the the inspection conducted on 09/19/2017. This report supersedes all other <br />versions which are dated prior to 10/02/2017. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of the receipt of this report <br />Red tag number 1294 was placed back on the 110-octane fill pipe and red tag number 1275 was placed back on <br />the 100-octane fill pipe. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, LIST Response Plan, LIST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: September 19, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />CESAR RUVALCABA, EHS Trainee <br />(209) 953-6213 <br />Brenda Vasquez, Manager <br />FA0004625 PR0231426 SC001 09/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.