Laserfiche WebLink
Ask <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj,gov.org/ehd <br />JIM <br />derground Storage Tank PragraM inspection Report <br />Facility Name: <br />QUICK SHOP <br />Facility Address: <br />2072 W YOSEMITE AVE, MANTECA <br />Date: <br />March 31, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR -Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. The annular sensor for the 87 product is listed <br />as model 470, which appears to be incorrect per technician. The monitoring plan must be uploaded to the California <br />Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br />for review by the EHD. <br />This is a Class II violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The UST Monitoring Site Plan does not include the liquid <br />sensor location for the 87 product and the 100 octane product liquid sensors located in the Submersible Turbine <br />Pump (STP) sumps. A site plan must be submitted identifying the locations where monitoring will be performed. <br />Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload <br />a copy of the UST Monitoring Site Plan. <br />This is a Class II violation. <br />111 <br />CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br />An annual monitoring system certification (MSC) and leak detector testing were performed on 9/23/2013 and on <br />2/27/2015, and on 3/22/2016. The annual monitoring system certification was due by 9/23/2016 per the 03/22/2016 <br />inspection. Testing has not been completed and is 6 months past due. The 100 and 110- octane monitoring <br />systems were not tested today. These tests are required once every 12 months. THe next routine UST inspection <br />and monitoring system certification is due by 9-23-2017. Take all necessary precautions to ensure testing is <br />performed in a timely manner. <br />This is a repeat violation, Class II. <br />112 <br />HSC 25284.2 Failed to test spill containers annually. <br />An annual spill container certification was performed on 9/23/2013 and on 2/27/2015, and on 3/22/2016. The <br />annual spill container certification was due by 9/23/2016 per the 03/22/2016 inspection. Testing has not been <br />completed and is 6 months past due. The 100 and 110- octane spill containers were not tested today. These tests <br />are required once every 12 months. THe next routine UST inspection and spill container certification is due by <br />9-23-2017. Take all necessary precautions to ensure testing is performed in a timely manner. <br />This is a repeat violation, Class II. <br />113 <br />CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br />A monitoring system certification, leak detector testing, and spill container testing were performed on 03/22/2016. A <br />test report has not been submitted to the EHD or the California Environmental Reporting System (CERS). A copy <br />of the test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br />This is a repeat violation, Class II. <br />FA0004625 PR0231426 SCO01 03/31/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />