COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />0 <br />9 <br />P E T R <br />SCALE, I- . I& -0- <br />0 <br />WE S T LOUIS E A VENUE <br />\ o <br />L- ------------------------- <br />ELECTRICAL SE DESCRIPTION <br />REPLACE E:'ISTING PETROLEUM TRICAL SYSTEM, AS REQUIRED. <br />GENERAL NOTES <br />ALL WORK, SHALL BE IN ACCORDANCE WITH CURRENTLY ADOPTED NEC., LOCAL <br />REQUIREMENTS, AND MANUFACTURER'S INSTRUCTIONS. <br />PRO'ADECONTROL. WIRING AS REQUIRED. 'iERIFY SIZES WITH MANUFACTURER'S <br />INSTALLATION PROCEDURES. PRO'/IDE 4 INSTALL NEW WIREWAY S, GUTTERS, <br />CONDUIT AND SEALOFFS, AS REQUIRED. "STALL OWNER -SUPPLIED EQUIPMENT. <br />COORDINATE IRRIGATION CONTROL REQUIREMENTS WITH LANDSCAPER <br />KEYNOTES <br />I. 3/4" CONDUIT 140MERUIN TO WIREWAY FOR SUBMERGED TURBINE PUMP WITH <br />1 2 - "O's 4 012 CU. GROUND, MIN- TYPICAL OF 3. <br />I 2. 3/4" CONDUIT 1-CMER.24 TO WIREWAY FOR DISPENSER H.V. WIRE PER <br />MANUFACTURER'S REQUIREMENTS. TYPICAL OF 2. <br />r------------------------�--- <br />00� <br />EXISTING <br />CONVENIENCE <br />STORE <br />2200 SQ. FT. - 40'/55' <br />1 <br />TRASH <br />S <br />L. E L E C T. S 1 <br />N <br />3. 3/4" INTERCO11hi1TURE CONDUIT TO WIREWAY. `/ERIFY / COORDINATE SIMS WITH <br />MANUFACTURER'S INSTALLATION PROCEDURES. TYPICAL OF 2. <br />4. 3/4" GARDR£ADERfUTURE CONDUITS TO WIREWAY'. PROVIDE CONTROL WIRING AS <br />REQUIRED (MINIMUM 4 WIRES). '/HRIFY / COORDINATE SCES WITH MANUFACTURER'S <br />INSTALLATION PROCEDURES. TYPICAL OF 2. <br />5. 3/4" CONDUIT FOR 32OW. SMH CANOPY LIGHTS. 2 - 'ID'S t 1 -'L CU. GROUND. <br />(REPLACES EAST. CANOPY LIG14TS). ARROWWEADS INDICATE NO. OF HCMERUNS. <br />6. 3/4" CONDUIT HOMERUN TO WIREWAY WITH 3/4" CONDUIT LOOPED FOR SUMP MCNITORS/ <br />TANK GAUGE PROBE. TYPICAL OF 3. <br />1. NEW E/TERIOR DIVIDED WIREWAY / GUTTER WITH SEALOFFS AS REQUIRED. <br />WEATHERPROOF. '/EMFY LOCATION WITH OWNER / SITE CONDITIONS. <br />8. NEW DISPENSER CONTROLS, TANK MONITOR. CA,IRDREADER CONTROLS, <br />IN EXISTING ELECTRICAL ROOM. PROVIDE CONTROL WIRING AS REQUIRED. <br />VERIFY / COORD. SIZES / LOCATIONS AND QUANTITIES OF CONDUITS <br />WITH MANUFACTURER'S INSTALLATION PROCEDURES, AND OWNER G.C. SHALL <br />BE RESPONSIBLE FOR A COMPLETE WORKING / OPERATING SYSTEM. <br />9. EXISTING ELECTRICAL DISTRIBUTION PANEL(S). NEW CIRCUITS REPLACE EXISTING, <br />EXCEPT LOW '/OLTAGE CARDRE.ADER AND MONITOR AND CANOPY LIGHTS TO <br />REPLACE E/ISTING AREA LIGHTS. PROVIDE 4 INSTALL NEW WIREWAYS, GUTTERS, <br />CONDUITS / SEALS, AS RECUIRED. INSTALL OWNER -SUPPLIED EQUIPMENT. <br />10. EMERGENCY SHUT-OFF SWITCH, WITH CONTROL WIRING FOR DISPENSERS / STP6. <br />001-IFIRM LOCATION WITH OWNER'S AGENT. <br />ll. CONFIRM 4 INCORPORATE, OR SUPPLY t INSTALL DEDICATEPASOLATED SINGLE POINT <br />GROUND SYSTEM FOR ALL NEW ELETRONIC EQUIPMENT. PLEASE REFER TO DETAIL. <br />SUMS SUPPRESSOR WILL BE PROVIDED BY QUIK STOP, INSTALLED BY CONTRACTOR, <br />IF PART OF THIS PROJECT. <br />12. 3/4" C. HOMERLN TO WIREWAY WITH 3/4' C. LOOPED BETWEEN FILL SUMPS. FOR FUTURE, <br />CLASS I, GROUP D LOCATIONS - SERVICE STATIONS <br />UNDERSROUND TANK <br />FILL OPENING <br />DIV.] ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS <br />WITHIN THE DIVISION I OR 2 CLASSIFIED LOCATION. <br />DIV. 2 UP TO 18 R1 ABOVE GRADE LEvEL WITHIN A HORIZONTAL RADIUS OF 10 <br />FT. FROM A LOOSE FILL CONNECTION AND WITHIN A HORIZONTAL RADIUS <br />OF 5 FT. FROM A TIGHT FILL CONNECTION. <br />VENT - DISCHARGING UPWARD <br />DIV. 1 WITH" 3 FT. OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. <br />DIV. 2 SPACE BETWEEN 3 FT. AND 5 FT. OF OPEN END OF '/ENT, EXTENDING IN <br />ALL DIRECTIONS. <br />DISPENSING DEVICE - PITS <br />DIV. I ANY PIT, BO'/., OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS <br />WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. <br />DISPENSING DEVICE - DISPENSER, OUTDOOR <br />_ DIv. 2 WITHIN 16 IN. HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE <br />FROM (1) THE DISPENSER ENCLOSURE OR ('2) THAT PORTION OF THE <br />DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING CGMPONENTS. <br />SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED <br />IN "Power Operated Olspensing DeVlees For Petroleum Products-, ANSIAIL <br />81-1990. <br />DIV, 2 UP TO 18 RJ, ABOVE GRADE LEVEL WITHIN 20 FT. HORIZONTALLY OF ANY <br />. EDGE OF ENCLOSURE. <br />REMOTE PUMP - OUTDOOR <br />DIV. I ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A <br />HORIZONTAL DISTANCE OF 10 FT. FROM ANY EDGE OF PUMP. <br />DIV. 2 WITHIN 3 FT. OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. <br />ALSO UP TO 16 IN. ABOVE GRADE LEVEL WITHIN 10 FT. HORIZONTALLY <br />FROM ANY EDGE OF PUMP. <br />W <br />b � <br />IC 01 <br />a< d< oa <br />�bVWV00� <br />xz=zb� <br />O W V to <br />g ma 1%x _- <br />9. d 11111 mW ox <br />� dU. VL LL <br />QUIK STOP <br />121 <br />1196 UJ. LOUSE AVE. <br />MANTECA, CA 95336 <br />(209) 239-2951 <br />SAN JOAQUIN COUNTY <br />AF'N 211-410-43 <br />w ALMN <br />E NOINEERING, INC. <br />PD. BOX 1025 <br />843 RISKE LANE <br />MST SACRAMENTO, CA 95691 <br />1916) 312-1888 <br />FAX 313-1112 <br />ewe 4F SWAM RTi4 <br />rnoAlrr OF iftim.wdsa+a m <br />JW bi" wr Y Ulm Pat *W AM= <br />*r4N r" r0M mal *CW nW K" <br />! app m OR POWAM t TM[ OMO" <br />Diu wr wnwM ►?1lM�IIIIfI. � Qum <br />stun e0-su l(G <br />COPYRIGHT 0 1997 <br />DRAM BY T G <br />CFKD'BY <br />MEL <br />DATE <br />19 Na" 91 <br />SOu <br />P.10' <br />JOB NO, j <br />43610 <br />8HEET TITLE <br />PETROLEUM <br />ELECTRICAL <br />SITE PLAN <br />PET -6 <br />OF 1 SHEETS <br />