COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'A1 Tank ACessories <br />C�) Attached Collar C) <br />This fiberglass attached collar, without flange, can <br />be used to surround the fitting(s) or manway. The <br />collar can be used with attached collar risers (as <br />shown below in I & J). I.D.'s can be 42" or 48". <br />Strap locations can be affected. <br />C� Attached Collar Riser (ACR) <br />IN <br />:01 <br />ff <br />Service Fittings <br />Secondary contained service fittings, typically -a . <br />4" NPT within a 6" NPT, allow the tank to be <br />connected to a <br />secondary <br />contained <br />piping <br />system. <br />Grommet Kits <br />When high water conditions <br />do not exist, electrical con- <br />nections and secondary piping l� <br />can be field installed on an i <br />attached collar riser using <br />optional rubber grommets. <br />Grommets are available in the following sizes: <br />3/4" for 3/4" O.D. electrical conduit <br />1" for 1" O.D. electrical conduit <br />2", 3" and 4" for 2", 3" & 4" O.D. FRP pipe <br />Each kit includes six (6) grommets. <br />Fiberglass Bulkhead <br />Coupling <br />The 3" FRP coupling is a two-piece fitting that is <br />This fiberglass attached <br />dl <br />collar riser by the contractor. <br />collar riser is intended for <br />The male and female sections; <br />use with a 42" or 48"dia- <br />/ <br />meter attached collar. <br />(This is sold separately. <br />adhesive cures. Each kit in- <br />See H.) Riser body is 42" <br />adhesive and instructions. <br />or 48" I.D., with a flat top <br />and a 22" or 32"diameter <br />friction fit cover within top. <br />This riser provides an en- <br />closure for a submersible <br />pump and also provides <br />a termination point for <br />double wall piping systems. <br />The bonding of riser to <br />collar is to be done by the <br />contractor. (Adhesive kits <br />are included.) <br />J <br />Watertight <br />Attached Collar Riser (AC ) <br />This fiberglass watertight <br />attached collar riser is in- <br />tended for use with a 42" <br />or 48" diameter attached <br />collar. (This is sold separately. <br />See H.) The riser body is <br />42" or 48" I.D. with a <br />24" by 30" oval opening. <br />This provides an en- <br />closure for a submersible <br />pump and also provides a <br />termination point for double- <br />wall piping systems. The <br />bonding of the riser to the <br />A;R\ <br />collar and the top to the riser <br />is done by the contractor. <br />(Adhesive kits are included.) <br />IN <br />:01 <br />ff <br />Service Fittings <br />Secondary contained service fittings, typically -a . <br />4" NPT within a 6" NPT, allow the tank to be <br />connected to a <br />secondary <br />contained <br />piping <br />system. <br />Grommet Kits <br />When high water conditions <br />do not exist, electrical con- <br />nections and secondary piping l� <br />can be field installed on an i <br />attached collar riser using <br />optional rubber grommets. <br />Grommets are available in the following sizes: <br />3/4" for 3/4" O.D. electrical conduit <br />1" for 1" O.D. electrical conduit <br />2", 3" and 4" for 2", 3" & 4" O.D. FRP pipe <br />Each kit includes six (6) grommets. <br />Fiberglass Bulkhead <br />Coupling <br />The 3" FRP coupling is a two-piece fitting that is <br />bonded to the attached <br />dl <br />collar riser by the contractor. <br />The male and female sections; <br />of the FRP coupling are <br />threaded together to hold + <br />the fitting in place while the r <br />f <br />adhesive cures. Each kit in- <br />cludes one 3" FRP coupling, <br />adhesive and instructions. <br />Electrical I <br />il <br />Coupling <br />The 1" electrical coupling kit is a three-piece fitting <br />which is bonded to the <br />attached collar riser by the <br />contractor. The male and <br />female sections are threaded ; <br />together to hold the electrical + i <br />coupling in place while the <br />adhesive cures. Each kit in- <br />cludes four 1 " steel couplings, <br />adhesive and instructions. i <br />C <br />