COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
For water table considerations on a ten <br />foot diameter tank over 12,000 gallon <br />capacity, see Xerxes TRU-CHEK' brochure <br />NO 3/92 HPE —10' worksheet). <br />9. Record dispenser readings prior to <br />performing the tank tightness test and after <br />the test is completed. Verify depending on <br />the tank size, that the maximum dispensing <br />rates as noted on the TRU-CHEK' data log <br />sheets aren't exceeded during the test. <br />10. Conduct the TRU-CHEK' procedures <br />as shown on the TRU-CHEK® data log <br />sheets. Note there are different log sheets <br />for 6'/8' diameter tanks and 10' tanks above <br />12,000 gallons. <br />• To increase the accuracy of the tank <br />tightness test, the applicator should use <br />water finding paste to pinpoint the <br />calibrated dipstick measurements. <br />11. After the test is completed: <br />• Remove the additional brine with a <br />pump and adjust brine level in the <br />reservoir to about mid -point in probe. <br />• Carefully replace the electronic probe <br />system checking again the upper and <br />lower alarm level positions. <br />12. Maintain the data log sheets as a <br />permanent record and/or submit to the <br />jurisdiction in question as needed. <br />13: If the tank tightness test fails, it is <br />recommended you repeat the test to verify <br />the results. If the test fails again, notify <br />Xerxes Corporation's Technical Services <br />Department - (612) 887-1890. <br />14. For additional TRU-CHEK' data <br />log forms, notify Xerxes Corporation, <br />7901 Xerxes Avenue South, Minneapolis, <br />MN 612-887-1866. <br />AX1hRXF=b <br />CORPORATION <br />7901 Xerxes Avenue South <br />Minneapolis, MN 55431-1288 <br />(612) 887-1890 • FA.X (61-) 887-1870 <br />OSP <br />Revised 7/94 <br />