My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
low <br /> PRODUCT PIPING SUMP TESTING <br /> Test Method By: 0 Manufacturer • Industry Standard o Professional Engr o Other(see below) <br /> Test Method Uses: G Pressure 0 Vacuum • Hydrostatic o Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Description Tank#1 Tank#2 <br /> Tank product Gasoline-87 Gasoline-91 _ <br /> Sump material FRP FRP <br /> Sump diameter (inches) 48" 48" <br /> Sump depth (inches) 53" 56" <br /> Height from tank top to highest 21" 22" <br /> piping penetration (inches) <br /> Height from tank top to lowest 17' 18" <br /> electrical penetration (inches) <br /> Method of sump attachment to tank Tank Collar Tank Collar <br /> Condition of sump prior to testing Dry Dry <br /> Portion of sump tested Entire Entire _ <br /> Is system programmed for fail-safe operation? Unknown Unknown _ <br /> Was fail-safe verified to be operational? No No <br /> Was sensor removed for testing? Yes Yes <br /> Was sensor properly replaced after testing? Yes Yes <br /> Depth of water level from tank top (inches) 24 25 <br /> Wait time for water level to stabilize (hr:min) 0:25 0:14 <br /> Test start time 10:45 AM 10:45 AM <br /> Initial Probe Reading 3.4904 5.0607 <br /> Test end time 11:00 AM 11:00 AM <br /> Final Probe Reading 3.4901 5.0606 <br /> Test duration (hr:min) 0:15 0:15 <br /> Change in water level (±0.0000 inches) -0.0003 -0.0001 <br /> Pass/Fail threshold (±0.0020 inches/}Hr.) 0.0020 0.0020 <br /> TEST RESULT PASS PASS <br /> Comments: <br /> © 2004 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.