2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2006-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2024 11:04:03 AM
Creation date
6/23/2020 6:48:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2011
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2006-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITCWING SYSTEM CERTHWATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC <br /> CERTIFICATION /TEST DATE: June 6, 2011 <br /> Al. FACILITY A2. OWNER <br /> Name Quik Stop Market#121 Name Quik Stop Markets, Inc. <br /> Address 1196 W.Louise Avenue,Manteca,CA 95336 Address 4567 Enterprise Street,Fremont,CA 94538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 <br /> Contact Michael Karvelot Contact Michael Karvelot <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified June 1,2011 Lic# 617238 A, B,Haz <br /> Inspector Jeff Wong Contact Dulcinea Covan <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> 61: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-91 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794380-303 ■ Annular Space or Vault Sensor Model: 0794380-303 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: FE Petro STP-MLD ■ Mechanical Line Leak Detector Model: FE Petro STP-MLD <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Tank#4 (Product): _ <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensor(s) Model: ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> 62: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5-6 Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ❑ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> _ WALTON <br /> Signature:9 - ENGINEERING,INC, <br /> Technician/Cert#: Curtis Carpenter/B37258 8020679 Date: ,June 6, 2011 <br /> ©2011 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.