My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 1:05:50 PM
Creation date
6/23/2020 6:48:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
310
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
El <br />Page 3 of 6 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />QUIK STOP MARKET #2121 <br />Facility Address: <br />1 W MANTFCA <br />at <br />June 02 2016 <br />UST System Observations <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />❑ V <br />o R <br />❑ COS <br />322 <br />CCR 2636(1)(2) <br />Line leak detector not installed <br />o V <br />o R <br />❑ COS <br />323 <br />CCR 2636(1)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket Installed or failed to provide a means to keep it empty <br />o V <br />n R <br />n COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />o V <br />o R <br />o COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V <br />❑ R <br />o COS <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V <br />o R <br />o COS <br />328 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V <br />❑ R <br />❑ COS <br />331 <br />HSC 25299(0(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R <br />❑ COS <br />332 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V <br />❑ R <br />❑ COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V <br />o R <br />❑ COS <br />334 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V <br />o R <br />❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not property sloped or Incorrectly located check valve <br />❑ V <br />o R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V <br />o R <br />❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />o V <br />c R <br />o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />u V <br />u R <br />o COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V <br />o R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Mainterrance violation <br />❑ V <br />❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V <br />❑ R <br />❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS f, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.