My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 1:05:50 PM
Creation date
6/23/2020 6:48:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
310
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.slaov.ora <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />QUIK STOP MARKET #2121 <br />W MANTECA <br />June 02 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />1) The response plan is not current and/or not approved by the EHD; the response plan uploaded into CERS was the <br />Consolidated Emergency and Response Contingency Plan and not the UST Response Plan. The response plan must <br />be uploaded to the Calitornia Environmental Reporting System (CERS). Immediately log into CERS, upload the <br />completed form, and submit for review by the EHD. A response plan was observed onsite. Ensure a copy is available <br />for inspection at any time. <br />2) The monitoring plan is not current and/or not approved by the EHD. The submitted monitoring plan indicates that <br />FE Petro leak detector is present in the 87 STP sump; VMI leak detector was observed onsite at this sump. This leak <br />detector was replaced under inspection from EHD on 11-16-15. The monitoring plan must be uploaded to the California <br />Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for <br />review by the EHD. <br />This is a Class II violation. <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Complete maintenance and monitoring records for the last three years were not found on site. No 2015 monitoring <br />system certification results were available onsite. These records shall be maintained on site for at least three years. <br />Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br />maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br />field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and monitoring <br />records for the last three years on site and submit copies to the EHD. <br />This is a Class II violation. <br />204 <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />The monitoring plan is not current and/or not approved by the EHD. The submitted monitoring plan and the monitoring <br />plan available onsite indicates that FE Petro leak detector is present in the 87 STP sump; VMI leak detector was <br />observed onsite at this sump. This 87 STP leak detector was replaced under inspection from EHD on 11-16-15. An <br />accurate copy of these plans shall be accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a Class II violation. <br />309 <br />CCR 2636(0(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />The Bravo box float and chain in the UDC 1/2 (87 and 91 octane) sump failed to stop the flow of product at the <br />dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop <br />the flow of product at the dispenser when it detects a leak. The service technician cleaned the floats and verified <br />functionality. T#* valliVorrecWon sus. <br />This is a repeat violation, Class 11. <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.