COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 1:05:50 PM
Creation date
6/23/2020 6:48:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
310
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br />SANAAQUIN <br />COUNTY <br />— <br />Environmental Health Department <br />FA0000848 PR0231430 SC001 05/22/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Facility Name: <br />QUIK STOP MARKET #2121 <br />Facility Address: <br />1196 W LOUISE AVE, MANTECA <br />Date: <br />May 22, 2018 <br />c �f 44... 1kfl1'Q�seiY/ : <br />Q <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />■ V ❑ R ■ COS <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑ COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />j CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V ❑ R D COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />❑ V ❑ R ❑ COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ V D R ❑ COS <br />g Sing%a eQTyPressU[IZ �IIng,w, ,,.,. <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />.. "Otti@rs l 110 orlS <br />2010 See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />�' I�IMARIE �'� Q�►TIONS �: � �-� <br />ffi rtt Ai t3 CCASS o 1NOt Na4ce to Comply <br />9 x. <br />Item # <br />Remarks <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The pipe layout was missing. A site plan must be <br />submitted identifying the locations where monitoring will be performed. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />FA0000848 PR0231430 SC001 05/22/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.