Laserfiche WebLink
0 <br />SAN:JOAQUIN <br />COUNTY— <br />— <br />• <br />Environmental Health Department <br />FA0000848 PR0231430 SCO01 05/22/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />e� r <br />NNWQa <br />Facility Name: Facility Address: Date: <br />QUIK STOP MARKET #2121 1196 W LOUISE AVE, MANTECA May 22, 2018 <br />'� SCi MA QF �[O�Li4T101S <br />g� CLAS ctNlNb` Nonce to Comply! <br />R�-'."` -s <br />Item # <br />Remarks <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on 5/25/2017 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by 6/24/2017 . This <br />information was received on 7/17/2017 resulting in a non-compliant status for this facility. An operator that receives <br />an inspection report shall have 30 days to submit a written response that includes a statement documenting <br />corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br />documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a Class II violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the secondary containment test on the <br />June 2017 through May 2018 designated operator monthly inspection report. The 12 inspection reports stated that <br />secondary containment testing wa performed on 8/4/2016 however the test results that were found on site stated <br />that the test was performed on 8/3/2016. Also on the March 12, 2018 DO monthly report the report states February <br />12th, 2018 however the alarm history states Marchl2, 2018. During the monthly inspection, the designated operator <br />shall check that all required testing and maintenance for the UST system have been completed and document the <br />dates they were done. Ensure that designated operators performing monthly inspections at this facility are including <br />all of the required information on the reports. <br />This is a repeat violation, Class II. <br />309 <br />CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br />The 87 grade Bravo box float and chain in Under Dispenser Containment (UDC) 3/4 secondary containment failed <br />to stop the flow of product at the dispenser when tested. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The service technician <br />clean out the float and verified functionality. <br />This was corrected on site. <br />This is a repeat violation, Class ll. <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The 91 grade UST spill container failed when tested. All USTs shall be equipped with a spill container that has a <br />minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into the primary <br />container or provide a means to keep the container empty. The Service technician on site, Anthony, Reyes replaced <br />the spill container with another spill container that was able to hold 5 gallons for at least 60 minutes under the <br />inspection of the EHD inspector. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />FA0000848 PR0231430 SCO01 05/22/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />