Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.si4ov.org/ehd <br />Einderglround Storage Programs„rts�ecttort Report <br />Q ,. .. -Tank <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #3125 <br />1580 W MAIN ST, RIPON <br />June 09, 2017 <br />SUMMARY OF `lIOLATIONS <br />N . <br />(CLASS t GLASS II or N,N - Notice to Comply) <br />Item # <br />Remarks <br />309 <br />CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br />The Diesel BRAVO FLOAT AND CHAIN in the 3/4 and 5/6 UDC sump failed to stop the flow of product at the <br />dispenser when tested. The service tech cleared debris out from the floats and retested them. Both floats passed. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 87-, 91-, and diesel -product fill and submersible turbine pump (STP) sumps. <br />Approximately 3 gallons were found in the 87 fill sump, 3 quarts were found in the 91 fill sump, 25 gallons were <br />found in the diesel fill sump, 1 cup was found in the 87 STP sump, 2 cups were found in the 91 STP sump, and 2 <br />quarts were found in the Diesel STP sump. If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. The service technician removed the liquid from all of the <br />fill and STP sumps. Ensure that all sumps and annular spaces are maintained free of liquid. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The Diesel VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br />passed. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by July 9,2017 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />FA0000684 PR0231476 SCO01 06/09/2017 <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />