Laserfiche WebLink
LINE LEAK DETECTOR (LLD) TEST REPORT <br />TEST DATE: June 10, 2015 <br />A1. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market #125 <br />3 <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />1580 W. Main Street, Ripon, CA 95366 <br />Gasoline - 87 <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />Phone # <br />610-657-6600 <br />Contact <br />Roger Batra <br />Contact <br />Debbie Markovich <br />A3. C UP A <br />VMI 99LD-2000 <br />Red Jacket FX <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />May 26, 2015 <br />21 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Elena Manzo <br />Resiliency (ml) <br />Test leak rate(9P ) h <br />contact <br />Veronica Freitas <br />Phone # <br />209.468-8257 <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS <br />Test Equipment Used: Va orless VMI LDT-890 <br />Tank number <br />1 <br />2 <br />3 <br />Product contained <br />Gasoline - 87 <br />Gasoline - 91 <br />Diesel <br />Leak Detector Type <br />MLLD <br />MLLD <br />MLLD <br />Leak detector makelmodel <br />VMI 99LD-2000 <br />Red Jacket FX <br />VMI 99LD-2000 <br />Serial number <br />13121202 <br />6289 <br />4101138 <br />Functional Element Holding (psi) <br />30 <br />21 <br />33 <br />Resiliency (ml) <br />Test leak rate(9P ) h <br />70 <br />3.00 <br />70 <br />60 <br />3.00 <br />3.00 <br />Pump pressure (psi) <br />30 <br />30 <br />33 <br />Metering pressure (psi) <br />17 <br />10 <br />19 <br />Pressure Restriction Reduction (psi) <br />13 <br />20 <br />14 <br />Length of Restriction Test (seconds) <br />30 <br />30 <br />30 <br />Full Flow Opening time (seconds) <br />2 <br />2 <br />1 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />JU11 <br />14 2016 <br />J. COMMENTS: J. ` ` "`- <br />1- WALTON <br />Signature: o 01 ENGINEERING, INC. <br />Technician: Jessie Wadkins 1835391 5307886•UT Data: June 10, 2015 <br />