My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T <br /> 6p d <br /> S°JdRCB,January 2002 <br /> Pa�ae _--of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 71 Tank Manufacturer X Industry Standard <br /> L-1 Professional Engineer <br /> U Other(.Specify) <br /> Test Method Used: J Pressure X Vacuum <br /> C1 Hydrostatic <br /> Lj Other(,S"pecijj,) <br /> Test Equipment Used:INCON SUMP TESTER <br /> - Equipment Resolution:.002 <br /> Tank#87 Tank#91/DSL Tank# Tank# <br /> Is Tank Exempt From Testing?' Yes X No <br /> Tank Capacity: Yes X No <br /> Yes No Yes No <br /> 12,000 12,000 <br /> Tank Material: FIBERGLASS FIBERGLASS <br /> Tank Manufacturer: TOTAL TOTAL <br /> CONTAINMENT CONTAINMENT <br /> Product Stored: GAS GAS/DIESEL <br /> Wait time between applying <br /> pressure/vacuum/water and 5 MIN 5 MIN 1 <br /> starting test: <br /> Test Start Time: <br /> 12PM I 12PM <br /> Initial Reading(R!): -10 HG -10 HG <br /> Test End Time: IPM IPM <br /> _ ____..__.__.- <br /> Final Reading(RF): -1OHG -IOHG <br /> Test Duration: IHR IHR <br /> Change in Reading(RF-R,): 0 0 <br /> Pass/Fail Threshold or Criteria: 0 0 <br /> Test Result: X Pass 0 Fail X Pass 0 Fail Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? X Yes !;� No NA X Yes No !_NA Yes ,J No 1 NA Yes No NA <br /> Was sensor properly replaced and <br /> verified functional after testing? X Yes f]No Li NA X Yes NcYes F;No (' NA Yes .No NA <br /> Comments— (include information on re airs made j•ior to testing, and reconnnended follotir-tr for failed testsi <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23, Section 2637(a)(6)1 <br />