My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_1997-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 12:44:18 PM
Creation date
6/23/2020 6:49:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2012
RECORD_ID
PR0231522
PE
2361
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231522_1532 N BROADWAY_1997-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In -Tank Gauging / SIR Equipent: 41 <br />1111 l�illillili� Pill 1111111111�1111 iiiiiiiii <br />TOM. "IMW <br />%-ompletc tucRUHU an%. %v;n -ffluc5t. <br />0 Yes U I No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />U Yes <br />0 N/A <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />Yes <br />13 No* <br />Was accuracy of system product level readings tested? <br />Yes <br />U No* <br />Was accuracy of system water level readings tested? <br />U Ye <br />N/A <br />OU <br />Were all probes reinstalled properly? <br />0 Yes <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />I <br />* In the Section H, below, describe how and when these deficiencies were or 8111 DC correctcu. <br />G. Line Leak Detectors (LLD): El Check this box if LLDs are not installed. <br />%_UMP1VtMV <br />tnu 1UUU <br />Yes <br />W to a.0 n Rak. <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br />(Check all that apply) Simulated leak rate: M 3 g.p.h.; U 0.1 g.p.h ; U 0.2 g.p.h. <br />No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />Yes <br />Was the testing apparatus properly calibrated? <br />No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br />N/A <br />or disconnected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions <br />N/A <br />or fails a test? <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />N/A <br />Yes <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: The Red Jacket FXIV Mechanical Line Leak Detector on the Unleaded line, failed gyf I the 3.0 .p.h. <br />, <br />simulated leak test. Stockton Service Station Maintenance was dispatched to the site at the time of failure for <br />replacement and re -test. <br />
The URL can be used to link to this page
Your browser does not support the video tag.