My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />Appendix VI SEP 21 2015 <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http:// .waterboards.ca.gov.) <br />MONITORING SYSTEM CERTIFICATION I� ENVIRONMENTAL <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Mid City Ca FO Re -gen Bldg. No.: KINGCA <br />Site Address: 13850 Devries Road City: Lodi Tap: 95242 <br />Facility Contact Person: Jonathan Pakele Contact Phone No.: 916-439-6042 <br />Make/Model of Monitoring System: Pnuemercator TMS 2000 Date of Testing/Servicing: 09/03/15 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br />Tank ID: UST#313/DieseV550 gallons <br />Tank ID: <br />u In -Tank Gauging Probe. <br />Model: MP -450 <br />Cl In -Tank Gauging Probe. <br />Model: <br />Ll Annular Space or Vault Sensor. <br />Model: LS -610 <br />a Annular Space or Vault Sensor. <br />Model: <br />u Piping Sump/ Trench Sensor(s). <br />Model: LS -600 <br />Cl Piping Sump/ Trench Sensor(s). <br />Model: <br />a Fill Sump Sensor(s). <br />Model: <br />a Fill Sump Sensor(s). <br />Model: <br />O Mechanical Line Leak Detector. <br />Model: <br />a Mechanical Line Leak Detector. <br />Model: <br />O Electronic Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />0 Tank Overfill / High -Level Sensor. <br />Model: mechanical/RA-200 <br />O Tank Overfill / High -Level Sensor. <br />Model: <br />o Other ecify equipment a and model in Section E on Pae 2). <br />O Other s ea equipment t e and model in Section E on Pa e 21. <br />Tank ID: <br />Tank ID: <br />a In -Tank Gauging Probe. <br />Model: <br />Ct In -Tank Gauging Probe. <br />Model: <br />O Annular Space or Vault Sensor. <br />Madel: <br />O Annular Space or Vault Sensor. <br />Model: <br />0 Piping Sump / Trench Sensor(s). <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />[3 FII Sump Sensor(s). <br />Model: <br />a Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />13 Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />0 Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />Ct Tank Overfill / High -Level Sensor. <br />Model: <br />Ct Other(specify a ui ment a and model in Section E on Pae 2). <br />0 Other (specj!X a ui ment tyge and model in Section E on Pa e 2). <br />Dispenser ID: <br />DispenseriD: <br />® Dispenser Containment Sensor(s). <br />Model: <br />0 Dispenser Containment Sensor(s). <br />Model: <br />Ct Shear Valve(s). <br />la Shear Valve(s). <br />® Di§penser Containment Floats and Chain(s). <br />Ef Dispenser Containment Floats and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />O Dispenser Containment Sensor(s). <br />Madel: <br />0 Dispenser Containment Sensor(s). <br />Model: <br />O Shear Valve(s). <br />a Shear Valve(s). <br />d Dispenser Containment Floats and Chain(s). <br />O Dispenser Containment Floats and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />Ct Dispenser Containment Sensor(s). <br />Model: <br />Ct Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Floats and Chains <br />O Dis enser Containment Floats and Chain(s). <br />'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - i certify that the equipment identified in this document was inspected /smiced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable ofnerati such reports, I have also attached a <br />copy of the report; (check all that apply): 0 System set-up � Alarm history reportD� �y s�n� b)u�n Becera for WT#1 N6 423 <br />Technician Name (print): Ruben Becerra Signature: 091031x1151125;49 <br />Certification No.: 10993/5302139 License. No.: 703190 <br />Testing Company Name: Sunwest engineering inc. Phone No.: 8( 88 ) 588-8737 <br />Testing Company Address: 4780 Cheyenne way, Chino CA 91710 Date of Testing/Servicing: 09/03/15 <br />Monitoring System Certification <br />QA/QC APPROVED <br />9/15/20153:19 Mustin Tre <br />Wednesday, September 16, 2015 brittanyl <br />Page 1 of 4 <br />12107 <br />2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.