r0V <br />C <br />g;r <br />Page 4 of 8 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum 0 Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Lake Test I Equipment Resolution: <br />Sump Diameter: <br />Sump <br />46" <br />Sump Depth: <br />60112" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />14" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />1711 <br />Condition of sump prior to testing: <br />Clean <br />Portion of Sump Tested' <br />2" above produc <br />Does turbine shut down when sump <br />sensor detects liquid (both product and <br />water)?* <br />❑ Yes ❑ No 0 NA <br />Turbine shutdown response time <br />N/A (see comment; <br />Is system programmed for fail-safe <br />shutdown?` <br />❑ Yes ❑ No 0 NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No 0 NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />1 5 min <br />Test Start Time: <br />15:00 <br />Initial Reading (Ri): <br />15.0" <br />Test End Time: <br />16:00 <br />Final Reading (RF): <br />15.0" <br />Test Duration: <br />1 hour <br />Change in Reading (RF-Ri): <br />0 <br />Pass/Fail Threshold or Criteria: <br />1/16" hr <br />Test Result: <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />0 Yes ❑ No ❑ NA <br />Was sensor properly replaced after <br />testing? <br />0 Yes LINO ❑ NA <br />Trans Sump <br />28" x 25" <br />Vent Sump <br />29" x 20" <br />30" <br />30" <br />Fiberglass <br />Fiberglass <br />7" <br />91, <br />16" <br />18" <br />Clean <br />Clean <br />t 2"above product <br />2" above product <br />❑ Yes ❑ No 0 NA I ❑ Yes ❑ No 0 NA <br />N/A <br />❑ Yes ❑ No 0 NA <br />❑ Yes ❑ No 0 NA <br />5 min <br />15:00 <br />15.5" <br />16:00 <br />15.5" <br />1 hour <br />0 <br />1/16" hr <br />E1 Pass ❑ Fail <br />0 Yes ❑ No ❑ NA <br />0 Yes ❑ No ❑ NA <br />N/A <br />❑ Yes LINO 0 NA <br />❑ Yes LINO 0 NA <br />lINs <br />15:00 <br />12.75" <br />16:00 <br />12.75" <br />1 hour <br />0 <br />1/16" hr <br />0 Pass ❑ Fail <br />0 Yes ❑ No ❑ NA <br />0 Yes ❑ No ❑ NA <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Done during Annual Monitor Certification. <br />Sump <br />❑ Yes ❑ No ❑ NA I <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Pass ❑ Fail <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />