Laserfiche WebLink
RECEIVED <br /> Appendix VI AUG 2 0 2018 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at htto://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL <br /> For Use By All Jurisdictions Within the State of California HEALTH DEPARTMENT <br /> Authority Cited.Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 23, California Code o/ <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Mid City Ca FO Regan KINGCA <br /> Facility Name: Bldg.No.: <br /> Site Address: 13850 Devrles Road,Lodi,CA 95242 <br /> Facility Contact Person: Jonathan Pakele Contact Phone No.: (916)439-6042 <br /> Make/Model of Monitoring System: Pnuemercator TMS 2000 Date of Testing/Servicing:8!712018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appmpriate boxes to Indicatespecific equipment insl ectediseiviced: <br /> Tank ID: UST#313/Diesel/550 gallons Tank ID: <br /> 0 In-Tank Gauging Probe. Model: MP-450 ❑ In-Tank Gauging Probe. Model: <br /> .❑Annular Space or Vault Sensor. Model: LS-610 ❑Annular Space or Vault Sensor. Model* <br /> - <br /> El Piping Sump/Trench Sensor(s). Model: LS 600 ❑ Piping Sump/Trench Sensor(s). Model: <br /> EI FII Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> E)Tank Overfill/High-Level Sensor. Model: Machaniml/RA200Tank Overfill/High-Level Sensor. Model: <br /> 0 Other(specify equipment a and model in Section E on Pae 2). Others c' equipment and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑FII Sump Sensor(s). Model: FII Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> El Other(specify equipmenLtype and model in Section E on Pa 2. Other(s2ocity equipment and model in Section E on Pace 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensoria). Model: Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). Dis enser Containment Floats and Chain(s). <br /> Dispenser 10: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: Dispenser Containment Senson(s). Model: <br /> ❑ Shear Valve(s). ® Shear VaMe(s). <br /> Dispenser Containment Floats and Chain(s). Dis enser Containment Floats and Cherie). <br /> Dispenser lD: Dispenser 10: <br /> ❑ Dispenser Containment Sensoria). Model: ❑ Dispenser Containment Sensoria). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chains Dis enser Containment Floats and Chain(s). <br /> 'if the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information(e.g.manufacturers'checklists) necessary to verity that this Information is correct <br /> and a Plot Plan showing the layout of monitorin equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): Lj System set-up ❑Alarm history report <br /> Technician Nanta(print): Ruben Becerra Signature:Ruben Becerra ea.m1&W.0TW WAT-07W <br /> Certification No.: 10993/5302139 License.No.: 703190 <br /> Testing Company Name:.SunWest Engineering Const.,Inc. Phone No.:888-588-8737 <br /> Testing Company Address:4780 Cheyenne Way,Chino,CA 91710 Date of Testing/Servicing:8/7/2018 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> QA/QC APPROVED <br /> 8/7/20182:56 PMTeresa Ant 1 2/21/07 <br />