My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: V200091 <br /> Complete the following checklist: <br /> El Yes El No' Is the audible alarm operational? <br /> ❑✓ Yes ❑ No' Is the visual alarm operational? <br /> ✓ Yes No• Were all sensors visually inspected,functionally tested,and confirmed erational? <br /> ❑✓ Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper operation? <br /> ✓❑ <br /> Yes <br /> No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> WA <br /> El Yes No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> ✓ WA detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors Initiate positive shut-down? (Check all that apply) <br /> ❑SumprTrench Sensors; ❑Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failureldisconnection? Yes; No. <br /> Q Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention <br /> WA valve is installed),is the overfill warning alarm visible and audible at the tank fill points)and operating property? If so,at what percent <br /> of tank capacity does the alarm r? 90 % <br /> El Yes' O No Was any monitoring equipment replaced? If yes, identity specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ❑✓ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)[]Product;❑Water. If <br /> es,describe causes in Section E,below. <br /> ✓ Yes No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,If applicable <br /> ✓ Yes No' Is all monitoring equipment operational permanufacturers specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Droptube also equipped with overfill prevention device. <br /> Also tested vent box and transition box sensors, both LS-600, passed and certified. <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.