My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />Monitoring System Certification <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facitty Name: MCI Kingdon Bldg. No.: <br />Site Address: 13650 Devries Rd. City: Lodi zip: <br />Facility Contact Person: Todd Hart is Contact Phone No.: 972-729.5671 <br />Make/Model of Monitoring System: Pneumercalor TMS2000 Date of Testing/Service: 2/20/07 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to Indicate specific equipment Inspected/serviced: <br />Tank ID: Diesel <br />ank ID: <br />✓❑ In Tank Guaging Probe. <br />Model: 450 <br />❑ In Tank Guaging Probe. <br />Model: <br />❑ Annular Space Sensor. <br />Model: LS610 <br />❑ Annular Space Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: ' L'S600 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />❑ Tank Overfill / High Level Samar. <br />Model: <br />Other equipment type and model in Section E on Pa e 2). <br />Other(specify anttype and <br />model In Section E on Page 2). <br />ank ID: <br />ank ID: <br />❑ In Tank Guaging Probe. <br />Model: <br />❑ In Tank Guaging Probe. <br />Model: <br />❑ Annular Space Sensor. <br />Model: <br />❑ Amular Space Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Stang Sensor(s). <br />Model: <br />❑Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />Other ispecify e ui ment type and model in Section E on P e 2). <br />0 other (specify ui ment type and <br />model in Section E on Page 2). <br />Dispenser ID: <br />Dispenser to: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Dimenser Containment Fioa s and Chain(s). <br />Disoen=r Float(s) a <br />Chain <br />Dispenser ID: <br />Dispenser lD: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Dispenser containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Disgenser Containment Fioa <br />Di riser Containment FI <br />Chain(s). <br />Dispenser ID: <br />ispenserID: <br />❑ Dispenser Containment sensor. <br />Model: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />10 shear Valve(s). <br />Di§R=r Containment Float and <br />al <br />DiseCriser Contait=nt FI s and Chain <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was Inspectediserviced In accordance with the manufacturers' <br />guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this information Is correct <br />and a Plot Plan showing the layout of monttoring equipment. For any equipment capable of generating such reports, i have also attached a <br />copy of the report; (check ap that apply): <br />F] system set-up ❑Alarm History Report <br />Technician Name: Dennis Cardenas <br />Certification No.: 10590 <br />Testing Company Name: Balch Petroleum <br />Site Address: 930 Ames Ave, Milpitas, CA <br />Signature:,.-- <br />Liscense No.: 396575 A / B/ C-10 / HAZ <br />Phone No.: 408-942-8686 <br />Date of Testing/Service: 2/20/07 <br />Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.