S A N,10 A Q U 1 N Environmental Health Department <br /> COUNTY <br /> E ur1Ft <br /> 4Storage4Tan � Report . <br /> .. fit....,.;,. ....'3F..�al�='*'`�tA.;4,<.,, <br /> Facility Name: Facility Address: Date: <br /> Verizon Business: KINGCA 13850 N DE VRIES RD, LODI August 07, 2018 <br /> r. <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements is V ❑R ❑COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump ❑V ❑R ❑COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards ❑V ❑R ❑COS <br /> ` 4. � s a " <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> MINN. <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> $ % 3 Y+ ,x .* rS; ' �+�.=r�t Q,4'•."��(`gF�.N�jGB tQ S`.O�•Jf� <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Current financial responsibility documents not submitted. <br /> Financial responsibility documents on CERS does not list the facility as being insured. Current financial <br /> responsibility documents are required to be submitted annually. Immediately log into the California Environmental <br /> Reporting System(CERS)at http://cers.calepa.ca.gov/,and upload the required documents. <br /> This is a repeat violation, Class II. <br /> FA0003848 PR0231547 SC001 08/07/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />