Laserfiche WebLink
S A N s1 V A Q U I N Environmental Health Department <br /> COUNTY <br /> — <br /> UnUlnd'- Irou d Stam Ta' k ro r`arrr lns ectro Rort x� <br /> y ,s g 9 � t 9, . p p <br /> Facility Name: Facility Address: Date: <br /> Verizon Business: KINGCA 13850 N DE VRIES RD, LODI August 07,2018 <br /> S�Mlii11Q 1t10LATIONS �$ <br /> c (Gl?A§ FC 1w IN�NOR NoBce to Comply) Y' <br /> Item# Remarks <br /> 320 CCR 2635(b)(2)Overfill prevention system not present or failed to meet overfill requirements. <br /> The mechanical flapper used as the overfill prevention system is not currently functional on the Diesel-UST.The <br /> onsite technician demonstrated that the mechanical flapper failed by removing the drop tube, and moving the float; <br /> the float failed to activate the flapper mechanism. Immediately discontinue deposition of petroleum into this tank <br /> until the component is repaired or replaced by a properly licensed,trained, and certified contractor under permit and <br /> inspection of the EHD. If the failed component can't be replaced immediately,there is a possibility that the diesel- <br /> UST system may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Onsite for routine inspection, annual monitoring system certification, and triennial overfill prevention inspection. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork within 30 days of receipt of the inspection report. <br /> Please be aware that as of January 1, 2014,facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Consent granted through phone from Jonathon Pakele,Verizon Building Engineer. <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 07,2018 Inspector. Inspector Phone: <br /> Printed Name and Title: AARON HANG, REHS (209)468-3453 <br /> Jonathan Pakele,Verizon Building Engineer <br /> FA0003848 PR0231547 SC001 08/07/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />