My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
2300 - Underground Storage Tank Program
>
PR0231574
>
COMPLIANCE INFO_1986-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 11:45:21 AM
Creation date
6/23/2020 6:49:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2004
RECORD_ID
PR0231574
PE
2361
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
01
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231574_4100 E FREMONT_1986-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (two pages per k) <br /> Page _ <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ S. CHANGE OF INFORMATION) ❑ 8. TEMPORARY SITE CLOSURE 'L <br /> (Check one item only) ❑ 7. PERMANENTLY CLOSED ON SITE I �fa <br /> �C 3.RENEWAL PERMIT (Specify mason-for local use only) (Specify change-forlocal use only) ❑ 8.TANK REMOVED 430 •�I1�0 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY IDK <br /> rG w- t 5 &5 9 lilQ <br /> LOCATION WITHIN SITE(Optionag 431 <br /> I.TANK DESCRIPTION7Z 11 O S <br /> TANK to k TANK MANUFACTURER COMPARTMENTALIZED TANK /I��Yes ❑ No <br /> If'Yes'.complete one pagdror aarh compartment. <br /> DATE INSTALLED(YEARIMO) - TANK CAPACITY IN GA ONS NUMBER OF COMPARTMENTS <br /> L9 <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> IL TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> �1. MOTOR VEHICLE FUEL -1a. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> '(Il marked,complete Petroleum Type) 91b. PREMIUM UNLEADED '3. DIESEL ❑ 8. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME( CAS If(from Hazardous Materials Inventory page) <br /> hem Hazardous Materials Inventory page) <br /> ❑ 4. HAZARDOUS WASTE(Includes <br /> Used Oil) <br /> 1 17195 UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH - ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check one item only) fR2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ❑ 4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 5. CONCRETE 1195. UNKNOWN <br /> (Check one item only) I2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL oi. FIBERGLASS/PLASTIC ❑ S. FRP COMPATIBLE W/100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED - ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑95. UNKNOWN433 DATE INSTALLED <br /> OR COATING <br /> ❑ 2.ALKYD LINING ❑ 4. PHENOLIC LINING ❑ S. UNLINED ❑99. OTHER For local use only) <br /> (Check one item only) �3�,,,� <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ❑ 3. FIBERGLASS REINFORCED PLASTIC F!'-". UNKNOWN 434 DATE INSTALLED <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4. IMPRESSED CURRENT ❑99. OTHER (Forlocal use only) <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that apply) R 1. SPILL CONTAINMENT 1.ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br /> K2. DROP TUBE 2. BALL FLOAT ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE <br /> FV 'TAN)41EM'DETEC7)ION"> . <br /> IF SINGLE WALL TANK Check all that apply), IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): <br /> 01. VISUAL(EXPOSED PORTION ONLY) ❑ S. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> AUTOMATIC TANK GAUGING(ATG) ❑ 8. VADOSE ZONE 2. CONTINUOUS INTERSTITIAL MONITORING <br /> 3. CONTINUOUS ATG ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> -04. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING 099. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑Yes ❑No <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.