Laserfiche WebLink
r <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> V_t,PIPING,CONSTRfJCT10N'(C(Ieekapthat apply) Pace ofy <br /> UNDERGROUND PIPING <br /> ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑ 1. PRESSURE 2. SUCTION " <br /> 3. GRAVITY ❑ 1, PRESSURE 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ' 1. SINGLE WALL <br /> MANUFACTURER K2. DOUBLE WALL ❑95. UNKNOWN ❑95. UNKNOWN <br /> MANUFACTURER DOUBLE WAIL ❑99. OTHER <br /> MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL ❑ 1. BARE STEEL <br /> MATERIALS AND ❑ 2. STAINLESS STEEL C17. GALVANIZED STEEL ❑ 6. FRP COMPATIBLE WI 100%METHANOL <br /> CORROSION ❑ 2.STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> PROTECTION �y❑{ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95. UNKNOWN 113. PLASTIC COMPATIBLE WITH CONTENTS ❑ 8. FLEXIBLE(HDPE) ❑99. OTHER <br /> LAI 4. FIBERGLASS 11 8. FLEXIBLE(HDPE) 1199. OTHER 114. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ S. STEEL W/COATING ❑ 9. CATHODIC PROTECTION ❑ S. STEEL W/COATING ❑95. UNKNOWN <br /> VII.PIPING LEAK DIETE'CTION(Check off that <br /> apply) <br /> UNDERGROUND PIPING <br /> SINGLE WALL PIPING ABOVEGROUND PIPING <br /> 0PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply):SI <br /> NGLE WALL PIPING <br /> 1 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 2. MONTHLY 0.2 GPH TEST <br /> C `3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> 4 S. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ S. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) <br /> ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> 7. SELF MONITORING <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑ 8. DAILY VISUAL MONITORING <br /> El9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check alf that apply): SECONDARILY CONTAINED PIPING <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH - <br /> PRESSURIZED PIPING(Check all that apply): <br /> AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> 0,.. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> DISCONNECTION ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> ❑ <br /> C. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITH FLOW SHUT OfF OR <br /> RESTRICTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: <br /> SUCTION/GRAVITY SYSTEM: <br /> 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ EMERGENCY GENERATORS ONLY(Check all that appl)) <br /> 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUAL ALARMS ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR <br /> RESTRICTION ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK <br /> ❑ 17. DAILY VISUAL CHECK <br /> 0004 <br /> OFF <br /> �2. CONT NUOUSADISPENSER PAN 3ENSORHF {5 <br /> DISPENSER CONTAINMENT VALVE <br /> �@T ❑ 4, PALLY VISUAL CHECK <br /> DATE INSTALLED ;.'.L AUDIBLE AND VISUAL ALARMS <br /> ❑ 5. TRENCH LINER/MONITORING <br /> 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6. NONE <br /> IX.OWNERIOPERATOR SIGNATURE <br /> I certify that l formation provided herein is true and accurate to best of my knowledge. <br /> SIGNA E F OW1;�ER/' RATOR �j� DATE <br /> NA OF O ER/OPERAT R(print) <br /> TITLE Of OWNEWOPERATOR <br /> Permit Number(Forlocaf use onty) Permit Approved(For local use onty) <br /> PertnR F�pira6on Data(Forlora/use only) <br /> CUPAFORM(4199) <br /> Formerly SWRCS Form 8 <br />