99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_2003-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
6/23/2020 6:50:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2012
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231628_25651 N HWY 99_2003-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Sped) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Pass/Fail Threshold or Criteria: <br />Sump # 1 <br />Sump # 2 <br />Sump # 3 <br />Sump # <br />7Diameter: 774291 <br />" X Pass ❑ Fail <br />42" <br />42" <br />Pass ❑ Fail <br />Was sensor removed for testing? <br />70" <br />70 %2" <br />70" <br />Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Yes ❑ No ❑ NA <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />17" <br />16" <br />17" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />4599 <br />43" <br />43" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested' <br />Water Level 20" <br />Water Level 20" <br />Water Level 20" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?" <br />X Yes ❑ No [INA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe <br />shutdown?* <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No [INA <br />Was fail-safe verified to be <br />operational?* <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />❑ Yes No ❑ NA <br />Wait time between applying water <br />and starting test: <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />8:20 <br />8:25 <br />9:10 <br />Initial Reading (RI): <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />8:50 <br />8:55 <br />9:40 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -RI): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005130 Minutes <br />Test Result: <br />" X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />JXYes ❑ No [INA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />