My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_2003-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
6/23/2020 6:50:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2012
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231628_25651 N HWY 99_2003-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page <br />8. UNDER -DISPENSER CONTAINMENT UDC TESTING <br />Test Method Developed By: <br />Test Method Used: <br />Test Equipment Used: Caldwell Le <br />UDC Manufacturer: <br />UDC Material: <br />UDC Depth: <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />Portion of UDC Tested <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />Was fail-safe verified to be <br />o erational?* <br />Wait time between applying <br />water and starting test <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />23" 23 ''/z" <br />10" 10 '/i" <br />6" 5" <br />Dry <br />Dry <br />Water Line 12" <br />Water Line 13" <br />X Yes No ❑ NA <br />X Yes No ❑ NA <br />Not Alarmed <br />Not Alarmed <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />5 Minutes <br />5 Minutes <br />11:35 <br />11:40 <br />.001 <br />.001 <br />12:05 <br />12:10 <br />.001 <br />.001 <br />30 Minutes <br />30 Minutes <br />0 <br />0 <br />.005/30 Minutes <br />.005/30 Minutes <br />X Pass ' ❑ Fail <br />X Pass 0 Fail Pass ❑ Fail <br />X Yes ❑ No ❑ NA <br />X Yes []No ❑ NA Yes ❑ No [INA <br />X Yes ❑ No [INA <br />X Yes ❑ No ❑ NA Yes ❑ No ❑ NA <br />of <br />Pass ❑ Fail <br />Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended folloiv-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.