My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:37:54 PM
Creation date
6/23/2020 6:50:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231659
PE
2361
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
01
SITE_LOCATION
2551 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231659_2551 E LOUISE_1985-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
! SWRCB,January 2002 0 0 Page 2 of 5 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: Industry Standard Test Method Used: Vacuum <br /> Test Equipment Used: Vacuum Gage 0"Hg —20"Hg Equipment Resolution: +/- 0.5"Hg <br /> Red Dye Diesel Tank <br /> Tank Exempt From Test?' ❑Yes ®No <br /> Tank Capacity, 550 gallons <br /> Tank Material: Fiberglas <br /> Tank Manufacturer: Xerxes <br /> Product Stored: Red Dye Diesel <br /> Wait after applying vacuum & test: 15 minutes <br /> Test Start Time: 2:45 PM <br /> Initial Reading (RI): -10" H <br /> Test End Time: 3:45 PM <br /> Final Reading (RF): -10" H <br /> Test Duration: 1 hour <br /> Reading Change(RF-RI): 0 <br /> Pass/Fail Criteria: +/- 0" H <br /> Test Result: ®Pass []Fail <br /> Sensor removed for test? ❑Yes ❑No DNA <br /> Sensor replaced and verified functional? ❑Yes ❑No DNA <br /> Comments—(include information on repairs made prior to test, and recommended follow-up for failed tests) <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and <br /> secondary containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from <br /> periodic containment testing. {California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.