My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:37:54 PM
Creation date
6/23/2020 6:50:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231659
PE
2361
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
01
SITE_LOCATION
2551 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231659_2551 E LOUISE_1985-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f ®SWRCB,January 2002 0 Page 4 of 5 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: Industry Standard Test Method Used: Hydrostatic <br /> Test Equipment Used: INCON TS-STS-3K Equipment Resolution +/-0.0001" <br /> _ .u. .z ....r ,. s,.,�k. .,,v . , 777._ <br /> � Transition <br /> ; 4r Turbine Sump <br /> Sump <br /> f <br /> Product Stored: Red Dye Diesel Red Dye Diesel <br /> Sump Manufacturer: Containment Solutions Bravo <br /> Sump Diameter: 48" 24" <br /> Sump Depth: 54" "28 <br /> Sump Material: Fiberglas Fiberglas <br /> Height from Tank to Top of Highest Piping Penetration: 16" Top Penetration <br /> Height from Tank to Lowest Electrical Penetration: 16" 16" <br /> Sump Condition before test: Clean/Dry Clean/Dry <br /> Portion of Sump Tested' 18" 18" <br /> Does turbine shut down if sump sensor detects liquid?* ❑Yes ❑ No FKNA ❑Yes ❑ No EINA <br /> Turbine shutdown response time ❑Yes ❑ No EINA ❑Yes ❑ No IHINA <br /> Is system programmed for fail-safe shutdown?* ❑Yes ❑ No ONA ❑Yes ❑ No SNA <br /> Was fail-safe verified to be operational?* []Yes ❑ No (EINA ❑Yes ❑ No EINA <br /> Wait time between pressurizing and start: 15 minutes 15 minutes <br /> Test Start Time: 10:40 AM 10:40 AM <br /> Initial Reading (Rj): 4.4166" 4.9799" <br /> Test End Time: 10:55 AM 10:55 AM <br /> Final Reading (RF): 4.4171" 4.9798" <br /> Test Duration: 15 minutes 15 minutes <br /> Change in Reading (RF-Rj): +0.0005 -0.0001 <br /> Pass/Fail Criteria: +0.004/-0.002" +0.004/-0.002" <br /> Test Result: ®Pass []Fail ®Pass []Fail <br /> Sensor removed for testing? ❑Yes ❑ No EINA ❑Yes ❑ No FENA <br /> Sensor replaced and verified functional after testing? ❑Yes ❑ No ❑x NA ❑Yes ❑ No I]NA <br /> Comments — (include information on repairs made and recommended follow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*) is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />