My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:37:54 PM
Creation date
6/23/2020 6:50:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231659
PE
2361
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
01
SITE_LOCATION
2551 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231659_2551 E LOUISE_1985-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> D. Results of Testing/Servicing <br /> MCI <br /> Software Version <br /> Installed: unknown 11/1/2005 <br /> Com lets the following checklist: <br /> x Yes No* Is the audible alarm operational? <br /> x Yes No* Is the visual alarm operational? <br /> HE <br /> x Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> x Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> interfere with their proper operation? <br /> FYeNo* <br /> No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> x N/A <br /> Fore pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down?(Check all that apply)_Sump/Trench Sensors _Dispenser Containment Sensors. Did <br /> you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes No. <br /> Yes No* For Tank systems that utilize the monitoring system as the primary tank overfill warning device(ie.,no mechanical <br /> HN/A overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and <br /> operating properly?If so,at what percent of tank capacity does the alarm trigger? % <br /> Yes _MNo Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and <br /> list the manufacturer name and model for all replacement parts in Section E,below. <br /> Yes _[RNo Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) _ <br /> Product; _Water. If yes,describe causes in Section E,below. <br /> Mx Yes No* Was monitoring system set-up reviewed to ensure proper settings?Attached set up reports,if applicable. <br /> TY--es- No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected: <br /> E,Comments: <br /> Monitoring System Certification <br /> Page 2 of 3 03/01 <br /> MCI-Lodi mon.cert.11-01-05.)ds <br />
The URL can be used to link to this page
Your browser does not support the video tag.