Laserfiche WebLink
t 4 <br /> DEC 2 0 2016 <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan <br /> The monitoring plan is not current and/or not approved by the Enyjp ental <br /> Health Department(EHD). Beneath Pipe Monitoring is Performed Using the <br /> Following Method(s), change "yes"to "no" for Suction Piping Meets <br /> Exemption Criteria. Beneath Record keeping, change "no"to "yes" for Alarm <br /> Logs and change "no"to "yes" for Visual Inspection Records <br /> UST Tank information/monitoring plan updated Item completed <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan <br /> The response plan is not current and/or not approved by the Environmental <br /> Health Department(EHD). The response plan still lists Doug Archer as a <br /> responsible person even though Doug Archer is no longer at this facility. The <br /> response plan must be uploaded to California Environmental Reporting System <br /> (CERS). Immediately log into CERS, upload the completed form, and submit <br /> for review by the EHD. Ensure a copy is available for inspection at any time. <br /> Emergency Response/ Contingency Plan and Training uploaded into CERS <br /> Item completed <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to <br /> completely show where the monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be <br /> submitted identifying the locations where monitoring will be performed. <br /> Immediately log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> UST Monitoring Site Plan uploaded into CERS Item completed <br /> 201 CCR 2712(b) Failed to maintain alarm log and/or records of follow up <br /> actions <br /> Monitoring records for the last three years were not found on site. Monitoring <br /> system certification test results for 2013 were not found on site. These records <br /> shall be maintained on site for at least three years. Monitoring records include: <br /> (1) date and time of all monitoring and sampling; (2) monitoring equipment <br /> calibration and maintenance records; (3) results of any visual observations; (4) <br /> results of sample analysis performed at a lab or in the field; (5) logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or <br /> other test results; (6) results of inventory readings and reconciliations. This was <br /> corrected on site Item completed <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or <br /> the inspection reports not completed. <br /> The designated operator failed to indicate that there were no alarms in the: <br /> 1/15/16, 2/18/16, 3/7/16, 5/19/16, 6/15/16, 7/14/16, 8/29/16, 9/19/16 and <br /> 10/21/16 designated operator monthly inspection reports. The designated <br /> operator checked"yes" for"Each alarm for the previous month has been <br /> responded to appropriately" when there was no alarm during the previous <br /> month. This was corrected on site. Item completed <br />