My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 12:42:29 PM
Creation date
6/23/2020 6:51:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231736
PE
2361
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231736_1420 N TRACY_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
485
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Adik <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.segov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SUTTER TRACY COMMUNITY HOSP 1420 N Tracy Blvd, Tracy November 04, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to indicate that there were no alarms in the: 1/15/16, 2/18/16, 3/7/16, 5/19/16, <br /> 6/15/16, 7/14/16, 8/29/16, 9/19/16, and 10/21/16 designated operator monthly inspection reports. The designated <br /> operator checked "yes"for"Each alarm for the previous month has been responded to appropriately"when there <br /> was no alarm during the previous month. This was corrected on site. There was no panel print out of alarms for the <br /> June 15, 2016 designated operator monthly inspection report. During the monthly inspection, the designated <br /> operator shall review the alarm history for the previous month, check that each alarm was documented and <br /> responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months. <br /> The November 2015 and October 2016 designated operator monthly inspection reports were not found on site. <br /> Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Ensure <br /> that copies of the previous twelve months of designated operator monthly inspection reports are maintained on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The diesel spill container contained about a cup of liquid. All USTs shall be equipped with a spill container that has <br /> a minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into the primary <br /> container or provide a means to keep the container empty. Continue to inspect the spill container and remove any <br /> liquid when present. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by December 4, 2016. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0002562 PR0231736 SCO01 11/04/2016 <br /> EHD 23-01 Rev.09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.