My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 12:42:29 PM
Creation date
6/23/2020 6:51:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231736
PE
2361
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231736_1420 N TRACY_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
485
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />C <br />4. TANK ANNULAR TESTING <br />Page of <br />Test Method Developed By: <br />x Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />x Vacuum <br />❑ Hydrostatic <br />Test Equipment Used: Dwyer Manometer <br />Equipment Resolution: +/- 2% <br />�Tank# 1 <br />Tank <br />Tank# Tank # <br />Is Tank Exempt From Testing? <br />❑ Yes x No <br />❑ Yes ❑ No <br />❑ Yes ❑ No ❑ Yes ❑ No <br />Tank Capacity: <br />10,000 <br />Tank Material: <br />Steel <br />Tank Manufacturer: <br />Unknown <br />Product Stored: <br />Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 min <br />30 min <br />30 min 30 min <br />Test Start Time: <br />9:17 <br />Initial Reading (Rj): <br />5.10 <br />Test End Time: <br />10:17 <br />Final Reading (RF): <br />4.49 <br />Test Duration: <br />1 hour <br />1 hour <br />1 hour 1 hour <br />Change in Reading (RF -RI): <br />.59 <br />Pass/Fail Threshold or Criteria: <br />No less than 1" <br />No less than 1" <br />No less than 1" No less than 1" <br />Test Result: < <br />x Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fall ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />x Yes ❑ No ❑ NA <br />x Yes ❑ No [INA <br />x Yes ❑ No ❑ NA x Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />x Yes El 11 NA <br />x Yes ❑ No ❑ NA <br />x Yes El No 11 NA x Yes 11 No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Annular space test performed after spill bucket test. <br />5.10 Start <br />4.9810 min <br />4.87 20 min <br />4.76 30 min <br />4.66 40 min <br />4.58 50 min <br />4.49 60 min <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.