Laserfiche WebLink
9 <br />Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov .) <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited. Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Tule 23, California Code ofilegulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator <br />owner/operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: AT&T Corporation Building No.: UE231 <br />Site Address: 110 W TURNER RD City: LODI Zip: 95242 <br />Facility Contact Person: Connie Mitchell Contact Phone No.: 209-474-4022 <br />Make/Model of Monitoring System: Veeder Root TLS -350 Date of Testing/Servicing: 5/9/2012 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: UE231U001 Tank ID: <br />F In -Tank Gauging Probe. Model: 847390-109 F In -Tank Gauging Probe. Model: <br />F Annular Space or Vault Sensor. Model 794390420 F Annular Space or Vault Sensor. Model: <br />Piping Sump/ Trench Sensor(s). Model: 794380-208 F Piping Sump/ Trench Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: F Fill Sump Sensor(s). Model: <br />F Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br />F Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br />P Tank Overfill / High -Level Sensor. Model: 790091-001 Tank Overfill/ High -Level Sensor. Model: <br />Other (specify equipment type and model in Sectio n E on Page 2). F Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: Tank ID: <br />F In -Tank Gauging Probe. Model: F In -Tank Gauging Probe. Model: <br />F Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br />F Piping Sump/ Trench Sensor(s). Model: F Piping Sump/ Trench Sensor(s). Model: <br />F Fill Sump Sensor(s). Model: F Fill Sump Sensor(s). Model: <br />Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br />Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br />F Tank Overfill / High -Level Sensor. Model: F Tank Overfill / High -Level Sensor. Model: <br />F Other (specify equipment type and model in SectionE on Page 2). i F Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: Dispenser ID: <br />Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s). Model: <br />Shear Valve(s). F Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID:_ Dispenser ID: <br />F Dispenser Containment Sensor(s). Model: F Dispense Containment Sensor(s). Model: <br />Shear Valve(s). F Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). I F Dispenser Containment Float(s) and Chain(s). <br />The <br />*If the facility contains more tanks or dispensers, copy this torn. Include information for every tank and dispense at the tacruty. <br />C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and <br />a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply) : P System set-up R Alarm history report <br />Technician Name (print): VictDr Guerrero <br />Signature: <br />Certification No.: B36532 License. No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br />Testing Company Address: 213] soUntnUPONTDRrvn~ ArAHBM,cA9M6 Date of Testing/Seryicing: 5/9/2012 <br />