My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
90
>
2300 - Underground Storage Tank Program
>
PR0231741
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:19 AM
Creation date
6/23/2020 6:51:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231741
PE
2361
FACILITY_ID
FA0003657
FACILITY_NAME
AT&T Corp. - UE231
STREET_NUMBER
90
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
CURRENT_STATUS
02
SITE_LOCATION
90 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231741_90 W TURNER_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software Version Installed: 127.04 <br />Complete the following checklist: <br />Yes <br />F No* <br />Is the audible alarm operational? <br />Yes <br />No* <br />Is the visual alarm operational? <br />y-- <br />I Yes <br />M <br />F No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes <br />No* <br />Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br />will not interfere with their <br />r o eration? <br />Yes <br />FN <br />=o <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem)operational? <br />F Yes <br />F No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br />� <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which <br />N/A <br />sensors initiate positive shut -down? (Check all that apply) <br />F Sump/Trench Sensors; F Dispenser Containment Sensors. Did you confirm positive shut -down <br />due to 1 eaks and sensor failure/disconnection? <br />F_ Yes; F No. _ <br />F Yes <br />F No* <br />For tank systems that utilize the monitoring system as the primary tank overfill waming device (i.e. no <br />r <br />mechanical overfill prevention valve is installed), is the overfill waming alarm visible and audible at the <br />N/A <br />tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? <br />€i% <br />_ <br />�Yes <br />F No <br />_.Vother equipment <br />�Was any monitoring equipment replaced? If yes, identify Nspecific sensors, �probes, <br />replaced and list the manufacturer name and model for all replacement arts in Section E, below. <br />F Yes* <br />F No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br />apply) Product; Water. If yes, describe causes in Section E, below. <br />Yes' <br />No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />Yes <br />No*� <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In SectionE below, describe how and when these deficiencies were orwill be corrected. <br />E. Comments <br />ter sensors from page one: <br />North Sump: 794380-208 / Certified <br />Gen. Room Trench: 794390-420 / Certified. <br />drop tube is equipped with a mechanical overfill prevention valve. <br />
The URL can be used to link to this page
Your browser does not support the video tag.