Laserfiche WebLink
D. Results of Testing/Servicing <br />Software Version Installed: 127.04 <br />Complete the following checklist: <br />Yes <br />F No* <br />Is the audible alarm operational? <br />Yes <br />No* <br />Is the visual alarm operational? <br />y-- <br />I Yes <br />M <br />F No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes <br />No* <br />Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br />will not interfere with their <br />r o eration? <br />Yes <br />FN <br />=o <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem)operational? <br />F Yes <br />F No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br />� <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which <br />N/A <br />sensors initiate positive shut -down? (Check all that apply) <br />F Sump/Trench Sensors; F Dispenser Containment Sensors. Did you confirm positive shut -down <br />due to 1 eaks and sensor failure/disconnection? <br />F_ Yes; F No. _ <br />F Yes <br />F No* <br />For tank systems that utilize the monitoring system as the primary tank overfill waming device (i.e. no <br />r <br />mechanical overfill prevention valve is installed), is the overfill waming alarm visible and audible at the <br />N/A <br />tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? <br />€i% <br />_ <br />�Yes <br />F No <br />_.Vother equipment <br />�Was any monitoring equipment replaced? If yes, identify Nspecific sensors, �probes, <br />replaced and list the manufacturer name and model for all replacement arts in Section E, below. <br />F Yes* <br />F No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br />apply) Product; Water. If yes, describe causes in Section E, below. <br />Yes' <br />No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />Yes <br />No*� <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In SectionE below, describe how and when these deficiencies were orwill be corrected. <br />E. Comments <br />ter sensors from page one: <br />North Sump: 794380-208 / Certified <br />Gen. Room Trench: 794390-420 / Certified. <br />drop tube is equipped with a mechanical overfill prevention valve. <br />