Home
Browse
Search
COMPLIANCE INFO_2004-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:30:52 PM
Creation date
6/23/2020 6:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2009
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\V\VICTOR\880\PR0231746\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />4. TANK ANNULAR TESTING <br />Page <br />of <br />Test Method Developed By: <br />❑ Tank Manufacturer VIndustry Standard ❑ Professional Engineer <br />O Other (Spec) <br />Test Method Used: <br />O Pressure <br />Cl Other (Spec) <br />'QVacuum <br />Cl Hydrostatic <br />Test Equipment Used: - " <br />7TExempt From Testing?' <br />Tank # <br />Yes ❑ No <br />Tank # 12Tank <br />)KYes ❑ No <br />Equipment Resolution: <br /># Tank # <br />Yes No ❑ Yes <br />❑No <br />ity: <br />Tank Material: <br />"r <br />Tank Manufacturer: <br />Product Stored: <br />S <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />`• v' <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />' <br />Final Reading (RF): <br />— it <br />Test Duration; <br />Change in Reading (RF-RO: <br />Pass/Fail Threshold or Criteria: <br />f <br />O Yes ONO DNA <br />O Yes O No O NA <br />❑ Yes ONO ❑ NA <br />Was sensor removed for testing? <br />❑ Yes ONO <br />❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />O Yes O No O NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ONO ❑ NA <br />O Yes ❑ No <br />❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for faileld tests) <br />—� �PS4 c-.Cj <br />------------- <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.