Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone. (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgoy.oWehd <br />Facift Name: Facility Address: li Date: <br />i <br />Marks Fuel & Food, Inc_ 880 E VICTOR -RD, LODI ept_ember 28 2015 <br />2010 <br />See below <br />WT, yStO <br />o V <br />o R <br />o COS <br />318 <br />CCR 2636(a) <br />Failed to have secondary containment <br />ED] V <br />D R <br />0 COS <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />m V <br />a R <br />o COS <br />320 <br />HSC 25290. 1 (c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion <br />o V <br />o R <br />u COS <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />Ei V <br />o R <br />o COS <br />322 <br />CCR 2636(0(2) <br />Line leak detector not installed <br />Ei V <br />o R <br />o COS <br />323 <br />CCR 2636(0(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />o V <br />o R <br />o COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />o V <br />o R <br />o COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />a V <br />n R <br />o COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />o V <br />c R <br />o COS <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />Ei V <br />o R <br />o COS <br />328 <br />HSC 25283.5 <br />Unburied below grade LIST failed to meet exemption status <br />Ei V <br />o R <br />o COS <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V <br />o R <br />o COS <br />330 <br />CCR 2717.1(0 <br />Deposited petroleum into a red tagged UST <br />o V <br />o R <br />ci COS <br />331 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />u V <br />Ej R <br />o COS <br />332 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V <br />o R <br />o COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />o V <br />o R <br />Ei COS <br />334 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />I o V <br />o R <br />o COS <br />ftedOlpinq,, <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />o V <br />o R <br />o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V <br />o R <br />Ei COS <br />403 <br />CCR 2643(4) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />o V <br />o R <br />E3 COS <br />404 <br />CCR 2643(e) <br />I Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V <br />o R <br />—77- <br />o COS <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />o V <br />o R <br />o COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />o V <br />o R <br />o COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />o V <br />o R <br />o COS <br />I <br />Received by Inspector: Phone: Date: <br />(initial): I FATINAH ZAREEF, REHS 1 (209) 953-7311 1 09/28/2015 <br />Page 3 of 6 <br />