My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />A- TANK ANNIli.AR TESTING NOV 2 8 2016 <br />Test Method Developed By: <br />❑ Tank Manufacturer ® Industry Standard ❑ Pr ti LTH <br />❑ Other (Spec) PER IUSERVICES <br />Test Method Used: <br />❑Pressure <br />❑ Other (Spec) <br />—1 vacuum <br />E] Hydrostatic <br />Test Equipment Used: VACUUM GAUGE <br />Tank # 87 <br />Is Tank Exempt From Testing? ® Yes ❑ No <br />Tank # 91 <br />® Yes ❑ No <br />Equipment Resolution: <br />Tank # DSL Tank # <br />❑ Yes ® No ❑ Yes ❑ No <br />Tank Capacity: <br />12000 <br />Tank Material: <br />STEEL <br />Tank Manufacturer: <br />UNKNOWN <br />Product Stored: <br />UNL <br />UNL <br />DSL <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5 MIN <br />Test Start Time: <br />12:10 <br />Initial Reading (Rj): <br />-10 <br />Test End Time: <br />1:10 <br />Final Reading (RF): <br />-10 <br />Test Duration: <br />1 HR <br />1 HR <br />IHR IHR <br />Change in Reading (RF -RI): <br />0 <br />Pass/Fail Threshold or Criteria: <br />0 <br />0 <br />0 0 <br />Test Result: <br />-11 <br />[] Pass ❑ Fail <br />❑ Pass ` ❑Fail <br />Pass ❑Fail . ❑Pass.: ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ❑ Yes [] No ❑ NA <br />_ Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />87 & 91 BRINE ANNULARS <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)) <br />Secondary Containment Test Results 2 of 7 <br />