COMPLIANCE INFO_1986-1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:28:27 PM
Creation date
6/23/2020 6:51:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1997
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_1986-1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
424
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK # <br /># I # 2. _ <br /># 2 <br />UST <br />SYSTEM DRAWING INFORMATION <br />CAPACITY <br />10 000 10 c400 <br />10000 <br />1. <br />_ (1) <br />Three complete sets of plans (include manufacturer's specification sheets for p installed). <br />2. <br />/ <br />Plans drawn to scale in non -erasable print. <br />0 <br />3. <br />/ <br />Plot plan to show location of tanks and all associated piping. NOV 2 4 1997 <br />4. <br />/ <br />Striker plates or drop tube -mounted bottom protectors illustrated below V g 1 T <br />5. <br />/ <br />Tank cross-sectional diagram. PERMIT/SERVICES <br />6. <br />/ <br />Detail of tank, associated piping, excavation and cover. <br />7. <br />- ! <br />Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Chapter 16, <br />_ C. <br />CORROSION PROTECTION <br />Article 3, Section 2631 (b) & 26353 <br />8. <br />- ` <br />Verification of product compatibility with the tank(s), piping, monitoring <br />U.L. LISTED <br />device(s), epoxy or silicone glues, etc. <br />9. <br />' <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. <br />10. <br />< <br />At the installation site, prior to installation, a tightness test shall be performed on both primary (10) and <br />_ (3) <br />secondary (20) contairynent systems before covering. [Section 2635 (a) (3) & (4)) <br />11. <br />! <br />Tank integrity test required upon completion of installation with tank in operating condition. Test results to be <br />submitted directly to PHS-EHD from the testing company or owner of facility. [Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (h)I <br />17 <br />TAur rfwDm TTTnu <br />TANK # <br /># I # 2. _ <br /># 2 <br /># <br /># <br />CAPACITY <br />10 000 10 c400 <br />10000 <br />_ (1) <br />MANUFACTURER <br />G'}Cleff-1NC� Tei �/1 <br />N <br />Vacuum applied to interstitial space. <br />Ze. <br />COMPOSITION <br />, <br />MODEL <br />(1) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />_ (2) <br />PRODUCT <br />_ (3) <br />Hydrostatic annular (primary tank pressure test). <br />_ C. <br />CORROSION PROTECTION <br />tank [Section 2635 (a) (2) (A)I <br />_ (1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />U.L. LISTED <br />etc.). <br />_ (2) <br />COMPATIBILITY WITH 100% <br />METHANOL <br />Y�5 <br />corrosion specialist. <br />13. TANK(s) TO BE <br />INSTALLED <br />A. <br />Steel -clad with <br />fiberglass reinforced plastic coatings, composites, or equivalent non-metallic exterior <br />coatings or coverings. <br />_ (1) <br />Tested at the installation site using an electric resistance holiday detector. <br />_ (2) <br />Vacuum applied to interstitial space. <br />Ze. <br />Fiberglass <br />(iSTift�j ) <br />(1) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />_ (2) <br />Vacuum applied to interstitial space. <br />_ (3) <br />Hydrostatic annular (primary tank pressure test). <br />_ C. <br />Non -clad steel <br />tank [Section 2635 (a) (2) (A)I <br />_ (1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />_ (2) <br />Field installed cathodic protection systems designed and certified as adequate by a <br />corrosion specialist. <br />_ (3) <br />Impressed current systems to be inspected no less than every 60 days. <br />5 <br />