My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Electronic Fuel Line Leak Detection I Veeder-Root Page 2 of 3 <br /> Spec <br /> V <br /> R E <br /> FEATURE OLLD PLLD <br /> LINE LEAK DETECTION <br /> 3gph Testing Yes Yes <br /> Precision Testing Option&fVVT9T HEAL-1 H <br /> Positive Shutdown - <br /> es Yes T14FN11 <br /> rd Party Certified Yes Yes <br /> INSTALLATION REQUIREMENTS <br /> Requires TLS Console Yes Yes <br /> Installs Without Breaking Piping Yes Yes <br /> Installs Without New Sump Yes Yes <br /> �nstalls Without New Wires No es <br /> *Not Available for flexible piping <br /> Specifications and Compatible Fluids Requirements <br /> The table below lists Veeder-Root Line Leak Detector specifications. <br /> SPECIFICATION PLLD WPLLD <br /> OPERATING TEMP -25 TO +1300 -25 TO +1300 <br /> UNLEADED GASOLINE <br /> LEADED GASOLINE UNLEADED GASOLINE <br /> 5% METHANOL/ 95% LEADED GASOLINE <br /> UNLEADED 5% METHANOL/ 95% <br /> 0 - 100% ETHANOL UNLEADED <br /> 10% ETHANOL/ 90% 10% ETHANOL/ 90% <br /> COMPATIBLE FUELS UNLEADED UNLEADED <br /> 15% MTBE/ 85% 15% MTBE/85% <br /> UNLEADED UNLEADED <br /> DIESEL DIESEL <br /> KEROSENE KEROSENE <br /> IET FUEL JET FUEL <br /> AVIATION GASOLINE AVIATION GASOLINE <br /> LINE FLOW RATE 120 GPM MAX. 120 GPM MAX. <br /> W/SWIFTCHECK VALVE W/SWIFTCHECK VALVE <br /> OPERATING RANGE 0 - 70 PSI 0 - 70 PSI <br /> PROOF PRESSURE 200 PSI 200 PSI <br /> MAX. VERTICAL PIPELINE HEIGHT <br /> ABOVETRANSDUCER 11 FEET 11 FEET <br /> .MINIMUM PUMP OUTPUT PRESSURE* 23 PSI 23 P—S1 <br /> *Pump output pressure should be a minimum of 4 PSI abovethecheck valve's relief pressure. <br /> All Veeder-Root Electronic Line Leak Detectors require a TLS-350 or TLS-4XX Console with <br /> installed system software versions shown in the table below. <br /> http://www.veeder.com/us/fuel-leak-detection/electronic-line-leak-detection-sensors 11/16/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.