My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0003834 PR0231784 SCO01 01/29/2018 <br />EHD 23-01 Rev. 09/22116 Page 3 of 6 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />Pro m, Inspection Report <br />UnderroundiStoraois Tan a <br />Facility Name: <br />PACIFIC AVENUE CHEVRON <br />Facility Address: <br />6633 PACIFIC AVE, STOCKTON <br />Date: <br />January 29, 2018 <br />UST System Obiervations <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />o V Ei R o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />ci V c R o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />Ei V c R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V o R o COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V u R ci COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V o R o COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />Ej V ci R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />E V ii R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />Ei V o R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />ii V c R o COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />Ei V o R o COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />Ei V o R o COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V c R o COS <br />Sing fe- [led: 1`460 -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />Ei V Ei R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V Ei R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />o V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />0 V o R Ei COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ci R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1), 2634(d) Failed to have an approved LIST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. On the monitoring plan for all three tanks, <br />beneath "Under Dispenser Containment (UDC) Monitoring", "UDC Monitoring Stops Flow of Product at Dispenser" <br />is incorrectly marked "Yes," and should be marked as "No." The monitoring plan must be uploaded to the California <br />Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br />for review by the EHD. <br />This is a minor violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The approximate location of the underground storage <br />tank piping is missing from the site plan. A site plan must be submitted identifying the locations where monitoring <br />will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a revised copy of the LIST Monitoring Site Plan. <br />This is a repeat violation, Class 11. <br />FA0003834 PR0231784 SCO01 01/29/2018 <br />EHD 23-01 Rev. 09/22116 Page 3 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.