P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AEGEIVEL <br />Page 3 of 3 <br />MAR 2 0 <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TEST MimpnKmApKiTm <br />Test Method Developed By: El UDC Manufacturer Z Industry Standard Fj Professioval Enginm, <br />[:1 Other (Specify) <br />Test Method Used: El Pressure El Vacuum Z Hydrostatic <br />Ej Other (Specify) <br />Test Equipment Used: See attached testing procedures. <br />Equipment Resolution: <br />UDC # 1-2 <br />UDC # 7-8 <br />UDC # 9-10 <br />UDC # 11-12 <br />UDC Manufacturer: <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />3019 <br />3099 <br />3099 <br />3019 <br />Height from UDC Bottom to Top <br />1019 <br />1099 <br />1099 <br />1099 <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />599 <br />599 <br />599 <br />599 <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />Fair <br />Fair <br />Fair <br />Fair <br />Portion of UDC Tested' <br />Above highest <br />Above highest <br />Above highest <br />Above highest <br />penetration <br />penetration <br />penetration <br />penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />El Yes El No Z NA <br />Elyes El No Z NA <br />El Yes El No Z NA <br />El Yes El No R NA <br />product and water)?* <br />Turbine shutdown response time <br />n/a <br />n/a <br />n/a <br />n/a <br />Is system programmed for fail- <br />E] Yes E] No Z NA <br />E]Yes [] No Z NA <br />E] Yes E] No Z NA <br />El Yes 0 No Z NA <br />safe shutdown?* <br />Was fail-safe verified to be <br />El Yes [:] No 0 NA <br />DYes E] No Z NA <br />El Yes E] No Z NA <br />El Yes E] No Z NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />starting test <br />Test Start Time: <br />11:21am <br />11:41am <br />10:51am <br />11:00am <br />Initial Reading (RI): <br />2.3959 <br />0.4384 <br />1.1023 <br />0.1949 <br />Test End Time: <br />11:36am <br />11:56am <br />11:06am <br />11:15am <br />Final Reading (RF)- <br />2.3959 <br />0.4384 <br />1.1030 <br />0.1948 <br />Test Duration: <br />15 min <br />15 1 <br />15 min <br />15 min <br />Change in Reading (RF -R,): <br />0.00002 <br />0.0000 <br />0.00076 <br />0.00014 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />0 Pass 0 Fail <br />0 Pass El Fail <br />0 Pass El Fail <br />Z Pass El Fail <br />Was sensor removed for testing? <br />Yes E]No [] NA <br />®Yes [:]No E]NA <br />®Yes E]No E] NA <br />®Yes E]No ❑ NA <br />Was sensor properly replaced and <br />®Yes [:]No El NA <br />®Yes [-]No [_]NA <br />®Yes E]No [:]NA <br />®Yes [:]No❑ NA <br />verified functional after testing? <br />I <br />I <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />6 month post repair compliance testing conducted as per San Joaquin County Permit SR0069 769 <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SVv'RCB LG -160) <br />