Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Pacific Avenue Chevron <br />Facility Address: <br />6633 PACIFIC AVE, Stockton <br />Date: <br />January 21, 2015 <br />UST System Observations <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V ❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R ❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />327 j <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2717.1(0 <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1. CLASS 11. or MINOR - Notice to Comolv) <br />Item # <br />Remarks <br />204 <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />On-line access to California Environmental Reporting System (CERS) was not provided to the employees during this <br />inspection, and an approved copy of the monitoring plans were not available for inspection. A copy of these plans shall <br />be accessible on site at all times. Immediately locate and retain a copy on site. This is a minor violation. <br />319 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />About 2 to 3 cups of liquid was observed in the 91 -octane STP and fill sumps. If water could enter into the secondary <br />containment by precipitation or infiltration, it must be removed and disposed of properly. The service technician remove <br />about 3 cups of liquid from each above-mentioned sump. Ensure that all sumps and annular spaces are maintained fre <br />of liquid. This is a Minor violation. This was corrected on site. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />Received by (initial): <br />Inspector: <br />JEFFREY WONG, Senior REHS <br />Phone: <br />(209) 468-0335 <br />Date: <br />01/21/2015 <br />