COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority, Cited:- Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulationv <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />p=aced for each monitoring system control panel by the technician who performs the work. A copy of this form mitst be <br />provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating <br />UST systems within 30 days of test date. <br />A. Genemi Information <br />Facility Name: SBC <br />Site Address: 907 LINCOLN ROAD <br />Facility Contact Person: <br />JEFF LAVA / CALVIN MUIR <br />GEO PAR # UE -046 CLLC Code: SKTNCAI I <br />City: <br />STOCKTON <br />Contact Phone No.: <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 <br />B. Inventory of Equipment Testeci/Certified <br />Cherk the sinnranriate boxes to indicate specific equipment inspected/serviced: <br />Zip: <br />559-442-2120 / 209-943-4128 <br />Date of Testing/Service: 8/17/05 <br />Tank ID: 1171 <br />Tank ID: <br />®In -Tank Gauging Probe: <br />Model: 847390-107 <br />❑In -Tank Gauging Probe: <br />Model: <br />®Annular Space or Vault Sensor: <br />Model: 794390-420 <br />[]Annular Space or Vault Sensor <br />Model: <br />®Piping Sump/Trench Sensor (s): <br />Model: 794380-352 <br />[]Piping Sump/Trench Sensor (s): <br />Model: <br />®Fill Sump Sensor (s): <br />Model: 794380-352 <br />[]Fill Sump Sensor (s): <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />[]Electronic Line Leak Detector <br />Model: <br />[]Electronic Line Leak Detector <br />Model: <br />®Tank Overfill/High-level Sensor: <br />Model: FEDERAL 350 <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Other, Specify a uia and model in Section E on Pae 2 <br />❑Other, S eci a ui . e and model in Section E on Pa e 2 <br />Tank ID: <br />Tank ID: <br />[]In -Tank Gauging Probe: <br />Model: <br />❑In -Tank Gauging Probe: Model: <br />[]Annular Space or Vault Sensor: <br />Model: <br />❑Annular Space or Vault Sensor <br />Model: <br />[]Piping Sump/Trench Sensor (s): <br />Model: <br />[]Piping Sump/Trench Sensor (s): <br />Model: <br />[]Fill Sump Sensor (s): <br />Model: <br />[]Fill Sump Sensor (s): <br />Model: <br />[]Mechanical Line Leak Detector. <br />Model: <br />[]Mechanical Line Leak Detector. <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Other, §pecify Specifya ui . =e and model in Section E on Page 2 <br />❑Other, Specify a ui a and model in Section E on Pa e 2 <br />Dispenser ID: <br />Dispenser ID: <br />[]Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chains <br />[]Dispenser Containment Floats and Chats) <br />Dispenser ID: <br />Dispenser ID: <br />[]Dispenser Containment Sensor(s): <br />Model: _ <br />[]Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s) <br />❑Dis enser Containment Floats and Chain s <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chains <br />❑Dis enser Containment Floats and Chain(s) <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br />this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating <br />such reports, I have also attached a copy of the report; (check all that apply): ® Systecp.se history <br />report <br />Technician Name (Print): RUBEN BECERRA Signature: <br />Certification No.: 0042 License No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714) 560-8222 <br />
The URL can be used to link to this page
Your browser does not support the video tag.