My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRC8, January 2002 <br />6. PIPING SUMP TESTING <br />Ll <br />Page of <br />Test Method Developed By: Sump Manufacturer ® Industry Standard Professional Engineer <br />Other (Specie) <br />Test Method Used: Pressure Vacuum ® Hydrostatic <br />Other (Spec i)�) <br />Test Equipment Used: INCON Equipment Resolution: .0000 <br />Sump # <br />Sump # Sump # <br />Sump # <br />Sump Diameter: <br />48" <br />Sump Depth: <br />381/2" <br />Sump Material: <br />FIBERGLASS <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />17" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />Condition of sump prior to testing: <br />OK <br />Portion of Sump Tested' <br />20" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />Yes No ® NA <br />Yes No ❑ NA <br />Yes No NA <br />Yes No NA <br />Turbine shutdown response time <br />N/A <br />Is system programmed for fail-safe <br />shutdown?' <br />Yes No ® NA <br />Yes No ❑ NA <br />Yes No NA <br />Yes No NA <br />Was fail-safe verified to be <br />o erational?* <br />Yes No ® NA <br />Yes No ❑ NA <br />Yes No NA <br />Yes No NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />10 MINUTES <br />Test Start Time: <br />11:10 / 11:26 <br />Initial Reading (R,): <br />5.4450 / 5.4449 <br />Test End Time: <br />11:25 / 11:41 <br />Final Reading (RF): <br />5.4447 / 5.4447 <br />Test Duration: <br />15 MINUTES <br />Change in Reading (RF -RI): <br />-.0003 / -.0002 <br />Pass/Fail Threshold or Criteria: <br />.0020 / .0020 <br />Test Result: <br />0 Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass 0 Fail <br />Was sensor removed for testing? <br />® Yes No NA <br />❑ Yes No NA <br />Yes No NA <br />Yes No NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />® Yes No NA <br />❑ Yes No NA <br />Yes No NA <br />Yes No NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.