My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />VersionLiquid Contact Product Detector UST Monitoring System: Models ILS 350 a3eta 3-,;n <br />/ Interstitial Liquid Sensor for_nks (0794390-420 <br />Evaluation Results (continued) <br />> Compiled Test Results for Qualitative Detector <br />Test Product Flow Rate: 0.12 ± 0.003 g la /hr. <br />' Specificity Reference: Regular Unleaded Commercial Gasoline <br />Product Activation Height - Calculated <br />Test Fuel Lower Detection Limit for 95% / 5% Condition <br />Regular Unleaded Commercial Gasoline 1.64 in (4.17 cm) <br />> Safety disclaimer: This test procedure only addresses the issue of the method's ability to <br />detect the presence of liquid product. It does not test the equipment for safety hazards. <br />Certification of Results <br />I certify that the point sensor liquid contact product detector was operated according to the vendor's instructions <br />and that the evaluation was performed according to the Third Party Procedures developed according to the U.S. <br />EPA's "Standard Test Procedure for Evaluating Leak Detection Methods: Liquid -Phase Out -of -Tank Product <br />Detectors."l I also certify that the results presented above are those obtained during the evaluation. <br />Margaret Nasta. Ph. D. <br />(printed name) <br />(signature) <br />July 17. 1992 <br />(date) <br />Carnegie Mellon Research Institute " <br />(organization performing evaluation) <br />P_iltstzj[gh. PA 15213 <br />(city, state, zip) <br />(412) 258-3475 <br />(phone number) <br />" Consultant to the Manufacturer <br />Liquid Contact Product Detector - Results Form Page 2 of 2 <br />Product <br />Response <br />Detection <br />Activation <br />Time <br />Recovery <br />Accuracy <br />Height <br />at a Flow Rate of <br />Time <br />0.12 ± 0.003 al/hr <br />Accuracy and <br />Response Time <br />Regular Unleaded <br />1.42 ± 0.03 in <br />6.51 ± 0.06 min <br />< 1 min <br />Commercial Gasoline <br />100% <br />(3.62 ± 0.08 cm) <br />6 tests <br />Sneclficlty <br />[104%]` <br />_ <br />Synthetic Fuel <br />100% <br />1.48 ± 0.02 in <br />5.85 ± 0.11 min <br />< 1 min <br />3 tests <br />(3.77 ± 0.06 cm) <br />[98•x6]' <br />Diesel Fuel <br />100% <br />1.39 ± 0.02 in <br />5.81 ± 0.05 min <br />< 1 min <br />3 tests - <br />3.53 ± 0.06 cm <br />[98%]` <br />Home Heating Oil #2 <br />100% <br />1.39 ± 0.02 in <br />5.88 ± 0.06 min <br />< 1 min <br />3 tests <br />3.53 ± 0.06 cm <br />[87%]• <br />Water <br />100% <br />1.23 ± 0.02 in <br />< 1 min <br />(3 tests) <br />(3.13 ± 0.06 cm) <br />5.48 ± 0.04 min <br />' Specificity Reference: Regular Unleaded Commercial Gasoline <br />Product Activation Height - Calculated <br />Test Fuel Lower Detection Limit for 95% / 5% Condition <br />Regular Unleaded Commercial Gasoline 1.64 in (4.17 cm) <br />> Safety disclaimer: This test procedure only addresses the issue of the method's ability to <br />detect the presence of liquid product. It does not test the equipment for safety hazards. <br />Certification of Results <br />I certify that the point sensor liquid contact product detector was operated according to the vendor's instructions <br />and that the evaluation was performed according to the Third Party Procedures developed according to the U.S. <br />EPA's "Standard Test Procedure for Evaluating Leak Detection Methods: Liquid -Phase Out -of -Tank Product <br />Detectors."l I also certify that the results presented above are those obtained during the evaluation. <br />Margaret Nasta. Ph. D. <br />(printed name) <br />(signature) <br />July 17. 1992 <br />(date) <br />Carnegie Mellon Research Institute " <br />(organization performing evaluation) <br />P_iltstzj[gh. PA 15213 <br />(city, state, zip) <br />(412) 258-3475 <br />(phone number) <br />" Consultant to the Manufacturer <br />Liquid Contact Product Detector - Results Form Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.