My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />California Edition: June 2001 <br />Veeder-Root <br />TLS -350 Series, TLS -300, 3001 <br />Discriminating Dispenser Pan Sensor (794380-322), <br />Discriminating Containment Sump Sensor (794380-352) <br />LIQUID -PHASE INTERSTITIAL DETECTOR <br />Detector: <br />Output type: qualitative <br />Sampling frequency: continuous <br />Operating principle: product permeable, reed switch/float <br />*The SWRCB strongly discourages the use of discriminating sensors for new installations in <br />California. (See notes on page 12 regarding discriminating sensors) <br />Test Results: <br />Discriminating Containment Sump <br />Sensor (794380-322) <br />Response time (sec) <br />Recovery time (sec) <br />Lower detection limit - height (cm) <br />Lower detection limit - thickness (cm) <br />Discriminating Dispenser Pan <br />Sensor (794380-352) <br />Response time (sec) <br />Recovery time (sec) <br />Lower detection limit - height (cm) <br />Lower detection limit - thickness (cm) <br />polymer strip <br />float switch <br />unleaded gasoline <br />diesel <br />water <br />high* <br />low* <br />--10 min <br />2-12 hrs <br /><1 <br /><1 <br />17.2 min <br />N/A** <br /><1 <br /><1 <br />N/D** <br />N/D <br />31.2 <br />3.48 <br />0.0127 <br />0.0127 <br />N/A <br />N/A <br />—10 min <br />2-12 hrs <br /><1 <br /><1 <br />17.2 min <br />N/A <br /><1 <br /><1 <br />N/D <br />N/D <br />19.4 <br />3.43 <br />0.0127 <br />0.0127 <br />N/A <br />N/A <br />*The "high" and 'low" refer to high and low level alarm points of float switch sensors. <br />** See glossary. <br />Specificity Results (in addition to above): <br />Activated: synthetic gasoline, jet -A fuel, n -hexane, toluene, xylene(s) <br />Not activated: water (polymer strip only) <br />Comments: <br />Polymer strip must be air dried after exposure to unleaded fuel. Polymer strips must be cleaned with <br />solvent and dried after exposure to diesel. <br />Veeder-Root <br />125 Powder Forest Dr. <br />Simsbury, CT 06070-2003 <br />Tel: (860) 651-2700 <br />Evaluator: Ken Wilcox Associates <br />Tel: (816) 443-2494 <br />Dates of Evaluation: 01/02/95, 06/23/97, <br />04/20/98 <br />263 <br />Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the <br />performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and <br />regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.