Laserfiche WebLink
& FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps r— <br /> Fill Riser Containment Sumps are present,but were Not Tested <br /> Test Method Developed By: F Sump Manufacturer 171 Industry Standard Professional Engineer <br /> r—Other(Specify) <br /> Test Method Used: r—Pressure F Vacuum � Hydrostatic <br /> F Other(Specify) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> ill Sump Fill S um Fill Sump Fill Sump <br /> UE046UO02 <br /> Sump Diameter: 4 <br /> Sump Depth: 80" <br /> Height from Tank Top to Top of <br /> 32" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 31" <br /> Electrical Penetration: <br /> Condition of sump priorto Good <br /> testing : <br /> Portion of Sump Tested: 2" above collar <br /> Sump Material: Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min. <br /> starting test: <br /> Test Start Time: 10:00 am 10:18 am <br /> Initial Reading(Rl): 3.7979 3.7974 <br /> Test End Time: 10:15 am 10:33 am <br /> Final Reading(Rd: 3.7974 3.7969 <br /> Test Duration: 15 min 15 min. <br /> Change in Reading(RF"RI): .0005 .0005 <br /> Pass/Fai 1 Threshold or Criteria: .002 .002 <br /> Test Result: F1 Pass r—Fail r— Pass r— Fail r— Pass Fail Pass F Fail <br /> Is there a sensor in the sump? 1-1 Yes No Yes No Yes [— No Yes No <br /> Does the sensor alarm when either <br /> product or water is detected? r— Yes r No r NA r Yes I No F NA I Yes No r NA r Yes r No NA <br /> �g <br /> g� <br /> Was sensor removed for testing? 1- Y. i - No i.. NA r- Yes r— <br /> No r— NA r— Yes r— No r NA F Yes No r— NA <br /> Was sensor properly replaced and �— es �— es �— r NA (� es r <br /> Ven es tied functional after testing? YNo NA YNo NA YNo YNo NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> __ _ _ ._...___. `.____.._.._. .�...®...... ....�.._... _..___ ......�._. ...e.. ..... .. ............._ .......-------.------- <br /> ._.. _.,.._..._ � _,...., ....�.,...... .. ,_,�,...� <br /> The sensor was reinstalled to the lowest point, but not tested. <br /> s <br /> s i <br /> i <br /> I <br /> i <br /> 3 <br /> i <br />