My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:56:31 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F.In-Tank Gauging/SIR Equipment: <br /> Check this box if tank gauging is used only for inventory control. <br /> * Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist <br /> Yes No* Has all input wrong been inspected for proper entry and termination including testing for ground faults? <br /> * Were all tank gauging probes visually inspected for damage and residue buildup? <br /> , m _. . <br /> Lr_— Yes No <br /> Yes F No* Was accuracy of system product level readings tested? <br /> Yes No* Was accuracy of system water level readings tested? ? <br /> F Yes No Were all probes reinstalled properly? <br /> Yes No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G.Line Leak Detectors(LLD): ' Check this box if LLDs are not installed. <br /> Complete the following checklist <br /> * <br /> Forequipment start-u,,.or a�.� <br /> Yes F No p nnual equipment certification,was a leak simulated to verify LLD performance?(Check <br /> F <br /> F N/A <br /> all that apply)Simulated leak rate: 3 gp.h.; 0.1 g.p.h; F' 0.2 g.p.h. <br /> ... <br /> F Yes F No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> Yes _ �.:.... <br /> IJ <br /> No* Was the testing apparatus properly calibrated? <br /> Yes No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> F' N/A <br /> * For electronic LLDs,does the turbine auto <br /> Yes � No automatically shut off if the LLD detects a leak? <br /> N/A <br /> * For electronic LLDs,does the turbine automaticallyshut off if a yµM vW ftmonitoring <br /> _ ito i <br /> F Yes Fx No_ any portion of the monitoring system is disabled or ? <br /> N/A <br /> disconnected? <br /> lic LLDdoes the turbine automatically shut off if any portion of the monitoring system m <br /> � Yes � No* For electronic s, malfunctions or <br /> N/A fails a test? <br /> Yes r No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> N/A <br /> F Yes F No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Suction System. <br />
The URL can be used to link to this page
Your browser does not support the video tag.